B-9

 

 

 

 

 

OPERATION

B-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE B.4

 

SET UP MENU PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Selection/

 

Parameter

Description

 

 

 

 

Symbol

* Default Value

 

Number

 

 

 

 

 

 

See Figure B.7

 

 

 

0

Set Up menu Exit

 

 

 

 

0

NA

 

 

1

Reset All Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% *

 

 

3

Start Current Set Unit

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A2

%

 

 

8

Bi-Level Current 2 Set Unit

 

 

 

 

Amps*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% *

 

 

10

Pulse Background Current Units

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%

 

 

17

Finish Current Set Unit

 

 

 

 

 

Amps*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 amps*

 

307

DC TIG HF STRIKE CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 amps*

 

306

DC LIFT TIG STRIKE CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 amps*

 

307

AC TIG HF TIG STRIKE CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled*

 

214

2-Step trigger re-start

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled

 

215

4-Step trigger re-start

 

 

 

 

 

Disabled*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Square*

 

 

 

 

 

 

 

 

 

 

Sine

 

 

101

AC Waveform Shape

 

 

 

 

 

Triangle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled

 

998

Bi-Level Trigger

 

 

 

 

 

Disabled *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled

 

999

Spot Timer Trigger

 

 

 

 

 

Disabled *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0ff*

 

 

 

 

 

 

 

 

 

 

VRD

Enabled to 12V

 

201

VRD Limit

 

 

 

 

Enabled to 20V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled to 30V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

Not Used

 

 

 

 

 

0 to 10

10*

 

552

Speaker Volume

 

 

 

 

 

 

 

-20 to 20

10*

 

553

Display Contrast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

English*

 

 

Display Language

 

 

 

 

 

French

 

 

554

 

 

 

 

 

Spanish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INVERTEC® V311-T AC/DC TIG

 

Page 24
Image 24
Lincoln Electric IM10051 manual Vrd, Table B.4 SET UP Menu Parameters