E-4

 

TROUBLESHOOTING

E-4

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE

RECOMMENDED

 

(SYMPTOMS)

 

CAUSE

COURSE OF ACTION

 

 

 

 

 

ELECTRICAL FAILURES

 

 

 

 

 

Machine fails to come on

1.

No Input Voltage.

 

(LCD screen and LED display do 2.

Faulty supply plug or cable.

 

not illuminate)

3.

Internal fuse blown.

 

 

 

4.

Input voltage not within range

 

 

 

 

 

Power output incorrect

1.

Incorrect setting up of the welding

 

 

 

 

parameters.

 

 

 

2.

Low mains supply voltage

 

 

 

 

 

No output current

1.

E01, E02, E03 DISPLAYED, and

 

 

 

 

the yellow control panel LED on.

 

Equipment Overheat. Allow machine to cool. The power should remain on so the fan can maintain airflow and cool the

machine

If all recommended possible areas of

2. E38 DISPLAYED• Input supply misadjustment have been checked

voltage dipped low.

and the problem persists, Contact

3. E39, E40 DISPLAYED

your local Lincoln Authorized

• Input supply voltage out of range

Field Service Facility.

or loss of phase .

 

4. E14, E15, or E18 DISPLAYED

 

• Internal memory errors. (Contact

 

your local Lincoln Electric

 

Authorized Service Facility.)

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.