E-4

TROUbLESHOOTING

E-4

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine goes to low idle but does not 1. Faulty Peripheral PCB, Pull

stay at low idle.Coil/Battery PCB or Weld Control PCB.

No welding output or auxiliary output. 1.

Broken lead in rotor circuit.

 

 

 

2.

Faulty field diode module.

 

 

 

3.

Faulty Weld Control PCB.

 

 

 

4.

Faulty rotor.

 

 

 

 

 

 

Welder has some/ no output and no 1.

Faulty remote kit.

 

 

control. Auxiliary output OK

2.

Faulty output control potentiome-

 

 

 

 

ter.

 

 

 

3.

Faulty output control wiring.

 

 

 

4.

Faulty Weld Control PCB, Pull

 

 

 

 

Coil/Battery PCB or Chopper PCB.

 

 

 

 

 

 

No welding output. Auxiliary output 1.

WELDING TERMINALS switch in

 

 

OK.

 

wrong position, be sure switch is

 

 

 

 

in WELDING TERMINALS

 

 

 

 

ALWAYS ON position.

 

 

 

2.

Faulty Weld Control PCB, Pull

 

 

 

 

Coil/Battery PCB or Chopper PCB.

 

 

 

 

 

If all recommended possible

areas

 

 

 

No auxiliary power.

1.

RCD may have tripped.

of misadjustment have

been

 

2.

Open breakers may need to be checked and the problem persists,

 

 

reset.

Contact your local Lincoln

 

3.

Faulty receptacle.

Authorized Field Service Facility.

 

4.

Faulty auxiliary circuit wiring.

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.