A-11

INSTALLATION

A-11

 

 

 

K529-10 POWER INPUT CABLE WITH WATER AND

GAS LINES

The K529 power input cable connects from the front of a Lincoln power source to the back of LN-7 and LN-7 GMA wire feeders equipped with a water solenoid control. K529-10 is 10 ft. (3.0m) long and includes two water hoses and a gas line. The lengths of the two water hoses and gas line are designed for proper con- nection to a Magnum Cooler and a gas cylinder locat- ed on the back of a Lincoln K874, K840-1*, K841-1* or K842-1* double cylinder undercarriage. The water connections are 5/8-18 left hand thread while the gas connection is 5/8-18 right hand thread. Reference Figure 8 when using the K529 power input cable.

* Not available at time of printing.

Figure 8

K529-10 POWER INPUT CABLE CONNECTION

 

SHIELDING

 

 

 

 

 

GAS

 

 

 

 

COOLANT

 

 

 

 

 

IN

WITHOUT

 

 

 

 

 

SOLENOID CONNECTIONS

 

 

 

COOLANT

 

 

 

 

 

OUT

 

 

 

 

CONTROL CABLE

COOLANT

 

 

 

 

 

IN

 

 

 

 

 

 

COOLANT

 

 

OUT

 

 

COOLANT

 

 

 

 

 

 

 

 

 

ELECTRODE CABLE

 

 

COOLANT

TO WORK

 

 

 

 

K529-XX

 

 

GUN CABLE

 

 

 

 

 

 

NOTE:

 

 

 

 

 

COOLANT

= BLUE HOSE

 

 

 

OUT

 

 

 

 

 

 

 

COOLANT

= RED HOSE

 

 

 

IN

 

 

 

 

 

 

MAGNUM COOLER 10-I & 20-I

Page 18
Image 18
Lincoln Electric IM438-B manual K529-10 Power Input Cable with Water GAS Lines, K529-10 Power Input Cable Connection