Lincoln Electric IM438-B manual Installation, Mig, Tig

Models: IM438-B

1 32
Download 32 pages 16.27 Kb
Page 8
Image 8

 

A-1

 

 

 

 

 

INSTALLATION

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – MAGNUM COOLERS 10-I AND 20-I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooler 10-I

 

Cooler 20-I

 

Product No.

 

K873-1

 

K879-1

 

 

 

 

 

 

 

 

 

 

 

Input

 

220V

50/60 Hz 1 Phase

 

220V 50/60 Hz 1 Phase

 

 

 

 

 

 

 

 

 

Current Draw at Input

.75 Amps

 

1.25 Amps

 

 

 

 

 

 

 

 

 

Rated Current Draw

1.0 Amps

 

1.6 Amps

 

 

 

 

 

 

 

 

 

Operating Pressure

45 psi (310 kPa) (3.0 bar)

 

60 psi (410 kPa) (4.0 bar)

 

 

 

 

 

 

 

 

 

 

 

Shutdown Pressure

 

60-65 psi (414-446 kPa)

 

 

 

(No delay after flow is

 

(4.0-4.4 bar)

 

 

 

stopped)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow Range

 

0.1 to 0.8 gal/min (0.4 to 3.0 liters/min)

 

 

 

 

 

 

 

 

 

 

Typical

 

MIG

with Magnum 15’ (4.5m) gun 0.55-0.60 gal/min (2.1-2.3 liters/min)

 

Operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow

 

TIG

with Magnum 12.5’ (3.8m) torch 0.25-0.30 gal/min (1.0-1.2 liters/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open Flow

 

0.8 (3.0 liters/min)

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir Size

 

 

2.0 ga. (8.0 liters)

 

 

 

 

 

 

 

 

Coolant Requirement

For Use Above Freezing: Tap, distilled, de-ionized, mineral water or well water.

 

 

 

 

 

 

 

For Use Below Freezing: 50% water and 50% automotive antifreeze mixture

 

 

 

 

 

 

 

such as Prestone, Peak or Zerex or 50% water and 50% pure ethylene glycol

 

 

 

 

 

 

 

mixture or any water alcohol mixture.

 

 

 

 

 

 

 

 

 

DO NOT USE: Prepackaged welding industry coolants. These coolants may

 

 

 

 

 

 

 

contain oil-based substances which attack the plastic components in the pump

 

 

 

 

 

 

 

of the Magnum Cooler and severely reduce pump life.

 

 

 

 

 

 

 

 

 

 

Weight

 

 

Shipping

30 lbs. (13.6 kg)

 

34 lbs. (15.4 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir

43 lbs. (19.5 kg)

 

47 lbs. (21.3 kg)

 

 

 

 

 

 

Full

 

 

 

 

 

 

Dimensions

 

L

9.0 in. (229mm)

 

9.0 in. (229mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

9.0 in. (229mm)

 

9.0 in. (229mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H Top Face

26.5 in. (673mm)

 

32.00 in. (815mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H Top

28.75 in. (730mm)

 

34.25 in. (870mm)

 

 

 

 

 

 

Handle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Undercarriage Use

K874

 

 

K840-1*, K841-1*, K842-1*,

 

 

 

 

 

 

 

 

 

 

K874

 

 

 

 

 

 

 

 

 

 

 

 

* Not available at the time of printing.

MAGNUM COOLER 10-I & 20-I

MAR97

Page 8
Image 8
Lincoln Electric IM438-B manual Installation, Mig, Tig