MAINTENANCE | ||
|
|
|
WARNING
ELECTRIC SHOCK can kill.
•Disconnect input power by removing plug from receptacle before working inside Cooler.
•Do not operate with covers removed.
•Use only grounded receptacle.
•Do not remove the power cord ground prong.
•Do not touch electrically “hot” parts inside Cooler.
•Have qualified personnel do the installation, main- tenance and troubleshooting work.
HEAT EXCHANGER MAINTENANCE
To maintain maximum efficiency, the heat exchanger should be kept clean from dust and dirt buildup. Clean the heat exchanger periodically using a vacuum hose or low pressure air line. Avoid placing the unit near a flux hopper or a flux waste container. A clean heat exchanger offers better cooling performance and longer product life. If extremely dirty conditions exist, it may be necessary to remove the heat exchanger completely from the Cooler for a thorough soap and water cleaning of the cooling fins. Use care to avoid damaging the fins.
RESERVOIR MAINTENANCE
The reservoir volume should be checked daily before using the Cooler. Remove the reservoir fill cap and check the coolant level. Unit is full when the coolant lies just below the reservoir fill opening with the unit in an upright position. Keep the reservoir full especially after changing the water lines.
The Cooler should always be operated with the reser- voir fill cap on. In areas where dust can be introduced into the reservoir through water lines or reservoir fill cap removal, periodically flush the unit out. Dump the old coolant and rinse the inside of the reservoir. Add new coolant when finished. A reservoir free from parti- cle buildup and dirt offers better cooling efficiency and longer pump, gun and torch life.
Both the
The
MAGNUM COOLER