OPERATION | ||
|
|
CONTROLS AND SETTINGS
UPPER CASE FRONT CONTROLS
Controls on the upper case front control panel are used for manual TIG and stick welding. Their func- tions are described below. Some controls are active in both TIG and stick welding, while others are active in TIG only. Refer to Figure B.1 for control locations.
|
| FIGURE B.1 – UPPER CASE FRONT CONTROLS | |||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
|
| 11 |
12 | 13 | 15 | 16 | 17 |
14 |
|
|
1. | REMOTE/LOCAL CURRENT CONTROL SWITCH | 7. | VOLTS/AMPS METER SWITCH | 12. | PREFLOW TIMER |
2. | MODE SWITCH (STICK/TIG) | 8. | AC WAVE BALANCE | 13. | SPOT CONTROLS |
3. | 9. | 14. | START CONTROLS | ||
4. | HIGH FREQUENCY SWITCH | 10. | AFTERFLOW | 15. | PULSE CONTROLS |
5. | DIGITAL VOLTMETER/AMMETER | 11. | STICK ARC FORCE | 16. | CRATER FILL CONTROLS |
6. | PEAK CURRENT CONTROL |
|
| 17. | STATUS INDICATOR LEDs |
SQUARE WAVE TIG 355