INSTALLATION | ||
|
|
OUTPUT CONNECTIONS
WARNING
ELECTRIC SHOCK can kill.
•Keep the electrode holder, TIG torch and cables insulation in good condition and in place.
•Do not touch electrically live parts or electrode with skin or wet clothing.
•Insulate yourself from work and ground.
•Turn the power off pushbutton on the Square Wave TIG 355 “off” before connecting or disconnecting output cables or other equipment.
See Figure A.3 for the location of the work and elec- trode terminals, the gas and optional water solenoids, and the Remote Receptacle.
TIG TORCH CONNECTION
TIG welding torches come with 15 ft (4.6m) and 25 ft (7.6m) cables. Use the shorter length whenever pos- sible to minimize possible radio interference problems. With power source off, connect the torch cable to the “Electrode” terminal on the welder. Connect a sepa- rate work cable to the “Work” terminal of the welder. See Table A.3 for recommended work cable sizes. Both work and electrode cables should be routed through the cable strain relief holes provided in the base directly below the welding ouput terminals.
Connect the TIG torch gas and water fittings to the welder fittings. any torch with fittings that conform to Compressed Gas Association (CGA) standards can be used.
The welder fittings have the following threads: Gas
Inlet and Outlet:
and Outlet:
WARNING
Observe the safety precautions necessary for handling and using compressed gas containers. Contact your supplier for specific information.
FIGURE A.3 – FRONT PANEL
1.REMOTE RECEPTACLE
2.WATER AND GAS SOLENOIDS
3.WORK (LEFT) AND ELECTRODE TERMINALS
TABLE A.3
CABLE SIZES FOR COMBINED LENGTHS OF COPPER ELECTRODE AND WORK CABLE
| Lengths up to | 100 to 200 ft | 200 to 250 ft |
Machine Size | 100 ft (30 m) | (30 to 61 m) | (61 to 76 m) |
|
|
|
|
350 Amp |
|
|
|
40% Duty Cycle | #1 (45mm2) | 1/0 (55mm2) | 2/0 (70mm2) |
|
|
|
|
SQUARE WAVE TIG 355