INSTALLATION

Welders are shipped connected for the highest input voltage as listed on the rating Plate. To change this connection for a different input voltage, reconnect the power strap (P) to the terminal corresponding to the input voltage used. Designations on reconnect panel, LOW, MID and HIGH correspond to the nameplate input voltages of a triple voltage welder. Dual voltage welders use only LOW and HIGH. Single voltage welders use only HIGH.

EXAMPLE: On a 208/230/460 volt welder, LOW is 208V, MID is 230V, and HIGH is 460V.

Fuse the input circuit with the recommended super lag fuses or delay type1 circuit breakers. Choose an input and grounding wire size according to local or national codes, refer to Specification page at the beginning of this chapter. Using fuses or circuit breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents even if not welding at high currents.

Unbalanced AC TIG welding draws higher input currents than those for stick, DC TIG, or Balanced AC TIG welding. The welder is designed for these higher input currents. However, where unbalanced AC TIG welding above 180 amps is planned, the higher input currents require larger input wire sizes and fuses. Refer to Specification page at the beginning of this chapter.

The Square Wave TIG 255 should be permanently wired into the power system. No plugs or connectors are necessary.

OUTPUT CONNECTIONS

WARNING

To avoid receiving a high frequency shock, keep the TIG torch and cables in good condition.

___________________________________________

See Figure 2 for the location of the work and electrode terminals, the gas and optional water solenoids, and the Remote Receptacle.

1Also

called

“inverse

time”

or

“thermal/magnetic”

circuit

breakers;

circuit

breakers which have a delay

in tripping action that

decreases

as the magnitude

of the current increases.

 

 

 

FIGURE 2 - FRONT PANEL

1

 

 

 

 

4

2

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D C

 

 

I

 

 

 

 

P O W E R

 

 

 

 

 

 

 

 

 

A C

D O N O T S W I T C H

 

 

 

 

 

W H I L E W E L D I N G

 

O

 

 

 

 

 

 

 

 

D C

W A R N I N G

 

W A T E R

W O R K

G A S

E L E C T R O D E

R E M O T E

O U T

I N

O U T

 

I N

 

 

 

 

7

 

 

5

6

 

8

1.

CONTROL AND DISPLAY AREA

5.

OPTIONAL WATER SOLENOID

2.

POWER SWITCH

 

6.

GAS SOLENOID

3.

THERMOSTATIC

 

7.

WORK (LEFT) AND

 

PROTECTION LIGHT

 

 

ELECTRODE STUDS

4.

POLARITY SWITCH

 

8.

REMOTE RECEPTACLE

TIG TORCH CONNECTION

TIG welding torches come with 12.5 ft (3.8m) and 25 ft (7.6m) cables. Use the shorter length whenever possible to minimize possible radio interference problems. With power source off, connect the torch cable to the “Electrode” stud on the welder. Connect a separate work cable to the “Work” stud of the welder. See Table 1 for recommended work cable sizes. Both work and electrode cables should be routed through the cable strain relief holes provided in the base directly below the welding output terminals.

TABLE 1

Cable Sizes for Combined Lengths of Copper

Electrode and Work Cable

 

Lengths up to

 

 

 

Machine Size

100 ft

100 to 200 ft

200 to 250 ft

 

 

 

 

 

 

255 Amp

#2 (35mm2)

#1 (45mm2)

1/0 (55mm2)

 

40% Duty Cycle

 

 

 

 

 

 

TIG torches include the necessary gas and, when designed for water cooling, water hoses. Connect the fittings on these hoses to the welder fittings. Any torch conforming to Compressed Gas Association (CGA) standards can be connected.

11

Page 11
Image 11
Lincoln Electric IM520-B manual Output Connections, TIG Torch Connection