C-1

C-1

ACCESSORIES

OPTIONS/ACCESSORIES

Synergic 7 wire feeder (K632-1) standard speed,or (K632-2) high speed

MAGNUM 400 gun (K471-2) or 550 gun (K598)

Remote control (stick welding) K941-1

Limits Overlay (K946-4)

Dual Wire Feeders, Dual Procedures Overlay (K946-9)

WIRE FEEDER SETUP

The Power Wave must be used with wire feeders list- ed above. Mount the feeder in a location suitable to your needs.

For most applications, connect the electrode cable between the feeder and the positive (+) connection of the power source. When negative electrode polarity is required, such as in some Innershield™ applications, connect the electrode cable between the feeder and the negative (-) connection of the power source. See Figure C.1.

FIGURE C.1 – WIRE FEEDER AND

WATER COOLER CONNECTIONS

1

2

3

5

4

Connect the control cable between the feeder and power source. The cable has different connectors on each end and will fit in only one way. If only one feed- er is used, it must be connected to the Feeder 1 Amphenol located on the back panel in the upper left- hand corner (as you view the machine from the back). If a second feeder is used, it must be plugged into the Feeder 2 Amphenol receptacle located just to the right of the Feeder 1 Amphenol receptacle.

Connect the work cable between the work and the negative (-) connection of the power source. When negative electrode polarity is required, such as in some Innershield™ applications, connect the work cable between the work and the positive (+) connec- tion of the power source. See Figure C.1.

Connect the feeder to a welding gas supply.

Load the wire into the feeder and gun.

Configure wire feeders (Refer to Setup overlay in operation section.

1WIRE FEEDER CONNECTIONS (LOCATION)

2WATER COOLER LINE (IN)

3WATER COOLER LINE (OUT)

4CIRCUIT BREAKER (WATER COOLER)

5FILL SPOUT (WATER COOLER)

Using a water-cooled gun is recommended to reduce the size of the gun and improve parts life. The Power Wave comes with a standard internal water cooler. However, an external cooler may also be used.

TABLE C.1 – RECOMMENDED GUNS FOR USE

WITH POWER WAVE 450

Gun

Application

Cooling

Product No.

MAGNUM 400

GMAW

Gas

K471-2

MAGNUM 550

GMAW

Gas

K598

 

 

 

 

GUNS AND CABLES

Several MAGNUM guns are recommended for use with the Power Wave as shown in Table C.1.

Place the proper liner in the gun and connect the gun to the feeder. Consult the specific instructions sup- plied with the gun for detailed operating instructions.

1Use of the Synergic 7 wire feeder requires appropriate input cable assembly, wire stand, and drive roll kit. Refer to Synergic 7 Operator’s Manual for available options.

POWER WAVE 450

11/96

Page 34
Image 34
Lincoln Electric IM579 manual Options/Accessories, Wire Feeder Setup, Guns and Cables