TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

OUTPUT PROBLEMS

 

Machine has no output – no fans –

1. Check for proper input voltage

 

no display. Main input fuses are

connections.

 

open, indicating excessive input

2. Make certain the reconnect

 

current draw.

 

panel is configured properly for the

 

 

 

 

applied voltage.

 

 

3. Replace the input fuses with

 

 

proper size and ratings. If the

 

 

fuses fail again, contact your local

 

 

Lincoln Authorized Field Service

 

 

Facility.

If all recommended possible areas

 

 

 

 

of misadjustments have been

 

 

checked and the problem per-

Machine has no output – no dis-

 

sists, contact your local Lincoln

play – fans run.

1. Check circuit breaker (5-amp)

Authorized Field Service Facility.

 

located on the front panel. Reset if

 

 

necessary.

 

Machine has no output – no dis-

1. Remove the feeder control cable

play – fans run – circuit breaker

from the machine. If symptoms

(5-amp) repeatedly trips.

disappear, feeder or control cable

 

 

is faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.