| INSTALLATION |
| ||
|
|
|
|
|
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
•TURN THE INPUT POWER OFF AT THE DISCONNECT SWITCH BEFORE ATTEMPTING TO CONNECT OR DIS-
CONNECT INPUT POWER LINES, OUTPUT CABLES, OR CONTROL CABLES.
•Only qualified personnel should perform this installation.
•Connect the green/yellow lead of the power cord to ground per appropriate National Electrical Code.
SELECT SUITABLE LOCATION
The Invertec
•The machine must be located where there is free cir- culation of clean air such that air movement in the back, out the sides and bottom will not be restricted.
•Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.
•Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.
STACKING
TILTING
Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.
INPUT AND GROUNDING CONNECTIONS
•Only a qualified electrician should connect the Invertec
•When received directly from the factory, multiple voltage machines are internally connected for 440VAC. If 440VAC is the desired input, then the machine may be connected to the power system without any setup required inside the machine.
•Initial 200VAC - 415VAC operation will require an Input voltage panel setup.
•Open the access panel on the rear of the machine.
•For 200 or 230: Position the large switch to
For higher voltages: Position the large switch to ≥ 380.
•Move the "A" lead to the appropriate terminal.
BLACK
GREEN/YELLOW
BLUE
BROWN
A
V
INV | ERTEC |
|
| V350- | |
|
| |
|
| PRO |
Single Phase Input
Connect green/yellow lead to ground per National Electrical Code.
Connect blue and brown leads to power.
Wrap black lead with tape to provide 600V insulation.
Three Phase Input
Connect green/yellow lead to ground per appropriate National Electric Code.
Connect blue, black and brown leads to power.
CONNECTIONS OF WIRE FEEDERS TO
•Turn the Invertec power switch "off".
•Connect the electrode cable to the output terminal of polarity required by electrode. Connect the work lead to the other terminal.
•
LN-7 Connection Instructions
•Turn the Invertec power switch "off".
•Connect the K480 control cable from the
•Connect the electrode cable to the output terminal of the polarity required by electrode. Connect the work lead to the other terminal.
•Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used. The wire feeder will now display the welding voltage.
•If K480 is not available, see connection diagram S19404 for modification of K291 or K404
•If a remote control such as K857 is to be used with the
S19901)
POWER CORD CONNECTION
A 5 meter power cord is wired into the machine.
Follow the power cord connection instructions.