B-4
OPERATION
B-4
TIG mode
The remote will default to the 6-pin amphenol if a
remote control is connected to the 6-pin amphenol
and one of the 14-pin amphenols. If a remote is not
connected to the 6-pin amphenol then the remote
will default to the 14-pin amphenols if a remote is
connected to one of the 14-pin amphenols.
If a remote control is connected to any of the
amphenols the WELD TERMINAL control will
default to REMOTE. If there are not any remote
control devices attached the WELD TERMINAL con-
trol will default to ON.
CC-Stick modes
The remote will default to only the 6-pin amphenol if
a remote is connected to it.
The WELD TERMINAL control will default to ON
with or without a remote connected.
Types of Remote OUTPUT CONTROL
The Invertec V350-PRO (CE)s Output Control can
be controlled by either a potentiometer connected
between 77 & 75 with the wiper connected to 76 or
a 0V to 10V DC supply connected between 76 & 75.
(76 needs to be positive)
14-Pin Amphenol lead 75 is pin G, lead 76 is pin F
and lead 77 is pin E.
6-Pin Amphenol lead 75 is pin C, lead 76 is pin B
and lead 77 is pin A.
Potentiometer Control
The total resistance should be between 2000 ohms
(2K) and 10,000 ohms (10K)
The machine output will be at minimum when lead
76 (wiper) is at the end of the potentiometer that is
connected to 75. The machines output will increase
as the wiper of the potentiometer is moved to the
end that is connected to 77. (Note: In TIG mode,
moving the lead 76 (wiper) to lead 77 would pro-
duce the current that has been set by the Invertec
V350-PRO (CE)s front panel Output Control.)
Remotes of this type offered by Lincoln Electric are
the K857, K812 and K870.
Voltage Control
The supply should be an isolated supply. (Not refer-
enced to earth ground, any auxiliary power from the
Invertec V350-PRO (CE) or the welding output)
The
supply should be capable of supplying at least 20mA.
0 volts supplied to 76 will set the Invertec V350-
PRO (CE) to minimum output for the mode that has
been selected while 10 volts supplied to 76 will set
the Invertec V350-PRO (CE) to the maximum output
for the mode. (Note: In TIG mode, 10 volts supplied
to lead 76 would produce the current that has been
set by the Invertec V350-PRO (CE)s front panel
Output Control.)
Types of Remote WELD TERMINAL Control
The Invertec V350-PRO (CE)s Weld Terminals can
be controlled from each of the amphenol connec-
tors. The circuit has a nominal OCV of 15VDC and
requires a dry contact closure (less than 100 ohms)
to activate the output of the Invertec V350-PRO
(CE).
14 Pin Amphenols the Weld Terminals are controlled
from pins C (lead 2) and pin D (lead 4). Pin C is posi-
tive.
6 Pin Amphenol the Weld Terminals are controlled
from pin D (lead 2) and pin E (lead 4). In the 6-pin
amphenol pin D is positive.
DESIGN FEATURES and ADVANTAGES
Multiple process DC output range: 5 - 425 amps
Pre-settable welding outputs.
Built-in Line Voltage Compensation holds the output
constant over +/- 10% input fluctuations.
State of the art inverter technology yields high
power efficiency, excellent welding performance,
lightweight, and compact design.
Utilizes microprocessor control.
Electronic over current protection.
Input over voltage protection
Manual reconnect switch located on the back panel
with a clear reconnect door to allow easy determina-
tion of input configuration. The reconnect door is
fastened with 1/4-turn connectors that allow quick
and easy access to the reconnect area. Circuit
breaker protected auxiliary.
System Self Configure. The power source analyzes
the remote controls connected to the amphenols
and the desired welding mode to properly determine
the location of trigger and output control.
Modular options for easy upgrades
Back lit Status Lights for improved error communi-
cation
Circuit Breaker Input Switch
F.A.N. (fan as needed). Cooling fan runs only when
necessary
Thermostatically protected.
Designed to the IEC 974-1 Standard.
IP21S protection rating with potted PC boards for
enhanced ruggedness/reliability.
Modular construction for easy servicing.
Aluminum Chassis and Wraparound
Power Cord included.
V350-PRO (CE)