B-2
OPERATION
B-2
5. THERMAL
This status light indicates when the power source
has been driven into thermal overload. If the output
terminals were "ON", the "ON" light will blink indicat-
ing that the output will be turned back on once the
unit cools down to an acceptable temperature level.
If the unit was operating in the "REMOTE" mode,
the trigger will need to be opened before or after the
thermal has cleared and closed after the machine
has cooled down to an acceptable temperature to
establish output.
6. CONTROL-REMOTE , LOCAL
Two status lights indicate the location of output con-
trol as pre-determined by the power sources auto-
configure system.
The LOCAL display will be lit when control is at the
power source.
The REMOTE display will be lit when a remote
pot/control is detected.
These Output Control configurations can be overrid-
den (switched) with the CONTROL push button.
When changed, the unit will power up in the configura-
tion it was in when it was last powered down.
Hidden Middle Control Panel ProcessSet Up Panel
The middle control panel is removable to allow for
upgrades (see Field Installed Options/Accessories).
Additionally, this panel is hidden by an access door to
reduce appeared complexity and provide protection to
the controls.
7. WELD MODE SELECT
The Mode Control button selects the following welding
modes desired.
CC-STICK SOFT: The Stick Soft process features
continuous control ranging from 5 to 425 amps. This
mode was intended for most SMAW applications, and
Arc Gouging.
Arc Gouging: Setting the output of the Stick Soft
mode to 425 amps will enable the arc-gouging
mode. The actual output current will depend on the
size of carbon used. The recommended maximum
size carbon is 5/16".
The Hot Start control regulates the starting current
at arc initiation. Hot Start can be adjusted from min-
imum (0), with no additional current added at arc
start, to maximum (10), with double the preset cur-
rent or 425 amps (max of machine) added for the
first second after arc initiation.
The Arc Control regulates the Arc Force to adjust
the short circuit current. The minimum setting (-10)
will produce a "soft" arc and will produce minimal
spatter. The maximum setting (+10) will produce a
"crisp" arc and will minimize electrode sticking.
CC-STICK CRISP: The Stick Crisp mode features
continuous control from 5 to 425 amps. This mode
was intended primarily for pipe welding applications.
The Hot Start control regulates the starting current
at arc initiation. Hot Start can adjust starting current
up or down by 25% of the preset value. The recom-
mended setting for Hot Start is 5 where the initial
current is equal to the preset current.
V350-PRO (CE)
OFF
OFF
OFF OFF
OFF
OFF
ON
ON
HO
HO
T ST
T ST
AR
ART
WELD MODE
WELD MODE
ARC CONTR
ARC CONTR
OL
OL
CC-STICK SOFT
CC-STICK SOFT
CC-STICK CRISP
CC-STICK CRISP
TIG GT
TIG GTAW
CV
CV
-WIRE
-WIRE
CV
CV
-FLUX CORED
-FLUX CORED
-4
+4
+4
+2
+2
-2 0
-6
+6
+6
-10
-10
SOFT
SOFT
CRISP
CRISP
+10
+10
-8
+8
+8
5
4
3
2
1
0
6
10
10
9
8
7
SELECT
SELECT
REMO
REMO
TE
TE
ON
ON
REMO
REMO
TE
TE
LOCAL
LOCAL
m
WELD
WELD
TERMINALS
TERMINALS
OUTPUT
OUTPUT
CONTR
CONTROL
SELECT
SELECT
SELECT
SELECT
MPS
MPS
A
OL
OLTS
V
16523487111012 9