F-7
DIAGRAMS
F-7
V350-PRO (CE)
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted insidethe machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number..FANFRONTOF MACHINEMAINXFMR
205
201
H3
H2
RECONNECT
H5
H4
NOTES:N.A. 1. FOR MACHINES WITH RED, BLACK AND WHITE POWER CORDS FOR SINGLE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRICAL CODE. CONNECT BLACK AND WHITE LEADS TO SUPPLY CIRCUIT. WRAP RED LEAD WITH TAPE TO PROVIDE 600V. INSULATION. FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT.
FAN
X10
X3
X20
X2
3
2
6
N.C.PLACE "A" LEAD ON APPROPRIATE CONNECTION FOR INPUT VOLTAGE. CONNECTION SHOWN IS FOR 550-575V OPERATION. (CE MODELS ONLY GO TO 440VAC.)ALEFT SIDE OF MACHINE
204
AA
208
B

G3707

WIRING DIAGRAM INVERTEC V350-PRO (CE)

REAROF MACHINE
X30
X40
X4
X
1
11-2000C
SEC
BOOST
RIGHT SIDE OF MACHINE
7
N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER.
206
( 380-575VAC POSITION )
207A 276
277
275
STATUSR5
10K/2W
POTCONTROL
277
275
13
24
DISPLAY
510
16
49
83
27
MODEC
O
NT
R
O
L
276
R(B)
BA
G(G/Y)
W
CB1
W(N)
V
C
B(U)
U
2
3
4
1
1
5
J4 J3J5J6J7J8J9J10A J10B
403
402
401
408
405
410
411
412
407
7
2
3
8
9
46 1
10
5
1112
2
3
4
1
502503 _+
10201002
H1
B
TP1 TP3
A
A
TP2
C
205
206 203
208
+
201
204
202 207
3200/300
C2,C4
xxxxxxx
209
SWITCH
207
209
207A
203
202
H6
575V
550- 460V
440- 230V
220-
380-
415V 208V
200-
H5H6H2H3H4 AUXILIARYH1XFMR
7
2
3
8
9
4
6
1
5
10
11
12
13
14
15
16
609602611607901903804903
72
38
94
6
1
105
2
2
3
41
5
78
9
10
2
3
1
6
5
4
7
8
802806801Y = YELLOWW = WHITEN = BROWNU = BLUER = REDG = GREENB = BLACKCOLOR CODE:
7
38
94
61
10
5
BRIDGEINPUT
2A
_
+A
BEFCD
_
901ELECTRICAL SYMBOLS PER E1537 PRIMARY
PRI-IN
PRI-OUT PRI-OUT
PRI-IN
SEC
BOOST
OUTPUTRECTIFIERCURRENTTRANSDUCER
502
505
L2REACTORCHOKEREACTORL1INPUTPERN.A.}
406
612608J34J31J311 J37J2J1
E
F
AB
C
D
802
804
801
806
4321
+
(REAR VIEW)
2A
4A
32
76A
21
R
E
M
O
T
E
17
410
93
28
J33 510
16
49
8
3
27
J331
7
42V
541
24
24V
16
42
COM1
77
4A
75
4
612
11
5
551
553
552
554
115V
P56P52
5
42
75
77 76
21
903A
901A
554 553
+
TP4
TP5
405
407
66
65
4
1
3
2
12
11
10
9
8
7
6
5
1
4
3
2
406
401
402
403
6
5
41
3
2
408
410
412
411
J43J41J42P
O
W
E
R
GASSOLENOID115V WIRE FEEDER
REMOTE
16
15
715
716
615616
615
607
611
612
3200/300
C1,C3+CONTROLRECTIFIER
54
65
2400/80
+C5
41A
~~
66
-+6 PIN
REMOTE
(REAR VIEW )
610605
41A
6
100 A CIRCUITBREAKER
SPI FLEXCIRCUIT
SPI FLEXCIRCUIT
SPI FLEXCIRCUIT
SPI FLEXCIRCUIT
N.C.
(REAR VIEW )
1
31
532
11
77A
GND 31
75A
77B
2B
4B
76B
ABCJKLDEM
I
HGFN
J21 3
1
J20
1
2
3
6
5
4
2608
I
605
616
610
X10
X30
66B 65B
J90
901B
903B
R1S1
2
1
6
12
CONNECTOR CAVITY NUMBERING SEQUENCE(VIEWED FROM COMPONENT SIDE OF BOARD)J43, J331
1
7
J8,J20,J21
4
8
1
5
J9, J42, P53
3
6
1
4
J2,J5,J11,J22, J41,J311, P55
21
4
3
J31,J33,J34,J37
6
5
10
1
J1,J6,J7, P52
8
16
1
9
CB2SNUBBER
X10
X2
X4
X20
X40
X30
75B
54
1
28V
432
438
431
432
438
431
CB2
532
32 P55
2
1551
552
4
3
21B
2
76
76A 77A
2A
75A
1
22
1010
1001
6
BASECASE FRONTPROTECTIVE BONDING CIRCUIT
GND
42
75B
77B
2B
4B
21B
76B
ABCJKLDEM
I
HGFN
41
24
CB1
541
41 41B
41B
24/42V WIRE FEEDER
REMOTE
J11
715
716
7
8
6
5
1020
1010
1001
1002
FAN
4
12
3
FAN
J22
COM2
115V
FAN
6A 2A
COM2
1001,1002,1010,102021,21B,2A,4A,75A,76A,77ASNB
6
7
84
609
602
503
xxxxxxx
506505 506J10A,J10B
COM2A
ON "CE" MODELS. N.D. INPUT POWER LINE FILTER IS PRESENT ONLY N.E. ON "CE" MODELS, MOV's ARE IN THE INPUT POWER LINE FILTER.N.D.N.E.LEGEND ALL MACHINES OPTION COMPONENT OUTLINE
GND
IN PARANTHESYS COLORSFOR CE MACHINESCONTROL MODE STATUS DISPLAYREMOTECONTROL MODE STATUS DISPLAYSPI FLEX CIRCUIT CONNECTION DETAILFOR MACHINES WITHOUT REMOTE BOARDFOR MACHINES WITH REMOTE BOARD 2. FOR MACHINES WITH BROWN, BLACK AND BLUE POWER CORDS FOR SINGLE PHASE INPUT: CONNECT GREEN/YELLOW LEAD TO GROUND PER NATIONAL ELECTRICAL CODE. CONNECT BLUE AND BROWN LEADS TO SUPPLY CIRCUIT. WRAP BLACK LEAD WITH TAPE TO PROVIDE 600V. INSULATION. FOR THREE PHASE INPUT: CONNECT GREEN/YELLOW GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLUE, BLACK & BROWN LEADS TO SUPPLY CIRCUIT.
ENHANCED DIAGRAM