1 PROGRAMMING LIMITS & FORCE

(Continuing from Installation Poster if provided)

SETTING & TESTING LIMITS AND FORCE

The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making adjustments using the panel located on the bottom of the powerhead. Begin with Step 1 and continue through Step 10. Door Force is set during the final Open/Close cycle of these steps. The powerhead will automatically set door speed at slow if the distance between limits is less than 6 feet. Once Limits and Force are set DO NOT use the or buttons to open or close door.

WARNING

Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property.

DO NOT operate this unit from wall console before LIMITS and FORCE are set. Severe damage to the opener can occur.

The bullet MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or refer to pages 11 and 19.

Genie Company

A) CLOSE DOOR TRAVEL LIMIT

NOTE: If bullet has NOT been engaged to the carriage, do so now.

Please note that there is a 30 second timeout between each programming step.

A programming timeout during these steps has occured when two RED flashing LEDs appear.

In the event of a timeout please restart at Step 1.

1PRESS and HOLD

PROGRAM

 

+

 

 

 

SET

 

 

 

 

SEE BOTH Blue LEDs come ON

2

RELEASE

SEE round

Blue LED come ON

3PRESS and RELEASE

PROGRAM

 

+

 

 

 

SET

 

 

 

 

SEE long Blue

LED come ON

If RED LED comes ON - STOP and

exit programming.

4

NOTE: If one or both LEDs come ON RED

 

at this time, Limits programming menu

12/2010

was not entered properly. You must exit

To exit the programming function wait 30

 

programming and restart.

 

seconds for the programming to time out.

 

 

 

 

 

 

 

PROGRAM

 

PRESS and

 

SET

 

 

RELEASE

SEE round Blue LED flashing

5PRESS and HOLD until door is FULLY CLOSED then RELEASE

OGRAM

 

+

 

 

 

SET

 

 

 

 

Watch door move

NOTICE

NOTE: You can start and stop door

movement using either buttons until door is in correct open or closed position.

Page 6
Image 6
Genie 4024H manual Programming Limits & Force, Close Door Travel Limit