TROUBLESHOOTING

E-2

E-2

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

 

 

Major physical or electrical damage

1.

Contact your local authorized

 

 

is evident when the sheet metal

 

Lincoln Electric Field Service

 

 

covers are removed.

 

facility for technical assistance.

 

 

 

 

 

 

 

 

Input fuses keep blowing, or input

1.

Make certain that the fuses or

 

 

breaker keeps tripping

 

breakers are properly sized. See

 

 

 

 

installation section of the manual

 

 

 

 

for recommended fuse and

 

 

 

 

breaker sizes.

 

 

 

2.

Welding procedure is drawing too

 

 

 

 

much output current, or duty

 

 

 

 

cycle is too high. Reduce output

 

 

 

 

current, duty cycle or both.

 

 

 

3.

There is internal damage to the

 

 

 

 

power source. Contact an autho-

 

 

 

 

rized Lincoln Electric Service

 

 

 

 

facility.

 

 

 

 

 

 

 

Machine will not power up (No

1. Make certain that the power

 

 

 

switch is in the "ON" position.

 

 

lights)

2.

The circuit breaker in the recon-

 

 

 

 

nect area may have opened.

 

 

 

 

Reset. Check input voltage sec-

 

 

 

 

tion below.

 

 

 

3.

Input voltage selection made

 

 

 

 

improperly. Power down, check

 

 

 

 

input voltage reconnect accord-

 

 

 

 

ing to diagram on reconnect

 

 

 

 

cover.

 

 

 

4. The 6 amp breaker may have

 

 

 

 

opened. Check for overload on

 

 

 

 

42VAC or 24VAC supply from the

 

 

 

 

14 pin MS-style connector.

 

 

 

 

 

 

 

 

Machine won’t weld, can’t get any

1.

If the displays show an Err ###

 

 

output.

 

see the fault section for correc-

 

 

 

 

tive action.

 

 

 

2.

If the displays are not lit refer to

 

 

 

 

machine will not power up sec-

 

 

 

 

tion.

 

 

 

3.

If the thermal symbol is lit refer to

 

 

 

 

the thermal section.

 

 

 

4.

If the output terminals are in

 

 

 

 

Remote control switch to "ON"

 

 

 

 

and check for output voltage. If

 

 

 

 

output voltage is now present

 

 

 

 

check for correct remote control

 

 

 

 

connection and operation.

CAUTION

If all recommended possible areas of misadjustment have been

checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.