TROUBLESHOOTING

 

E-3

E-3

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

Thermal symbol is lit

1. Check for proper fan operation. If

 

 

 

 

 

fan is not operating correctly the

 

 

 

 

 

CB 2 breaker may have opened.

 

 

 

 

 

Check for an overload on the

 

 

 

 

 

115VAC. Blow air in rear louvers

 

 

 

 

 

to remove dirt from around fan.

 

 

 

 

 

2. Check for material blocking

 

 

 

 

 

intake or exhaust louvers.

 

 

 

 

 

3. Blow air in the rear louvers to

 

 

 

 

 

clear dirt from the fan.

 

 

 

 

 

 

 

 

 

Wire feeder won’t work. Apparently

1. Check circuit breakers by the

 

 

 

no power to wire feeder

wire feeder receptacles on the

 

 

 

 

 

rear of the machine. Reset

 

 

 

 

 

2. Check the control cable between

 

 

 

 

 

the power source and the wire

 

 

 

 

 

feeder for continuity.

 

 

 

 

 

 

 

If all recommended possible

areas

 

 

 

 

 

 

 

 

of

misadjustment have

been

 

 

 

 

checked and the problem persists,

 

 

 

 

Contact your local Lincoln

 

 

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.