Lincoln Electric IM742-A manual Stopping, Welder Operation, Typical Ranger 305G Fuel Consumption

Models: IM742-A

1 52
Download 52 pages 8.81 Kb
Page 20
Image 20

B-4

OPERATION

B-4

 

 

 

The engine will run at high idle speed for approxi- mately 12 seconds and then go to low idle speed. Allow the engine to warm up at low idle for several minutes before applying a load and/or switching to high idle. Allow a longer warm up time in cold weath- er.

CAUTION

Operating the starter motor for more than 5 sec- onds can damage the motor. If the engine fails to start, release the switch and wait 10 seconds before operation the starter again. Do NOT push the START button while the engine is running because this can damage the ring gear and/or the starter motor.

------------------------------------------------------------------------

NOTE: When starting a RANGER 305G for the first time, or after and extended period of time of not oper- ating, it will take longer than normal because the fuel pump has to fill the fuel line and carburetor.

STOPPING

Remove all welding and auxiliary power loads and allow the engine to run at low idle speed for a few minutes to cool the engine.

Stop the engine by placing the RUN-STOP in the STOP position.

NOTE: A fuel shut off valve is not required on the RANGER 305G because the fuel tank is mounted below the engine.

WELDER OPERATION

Stick Welding

The RANGER 305G can be used with a broad range of DC stick electrodes.

The MODE switch provides two stick welding settings as follows:

Constant Current (CC-STICK) Welding

The CC-STICK position of the MODE switch is designed for horizontal and vertical-up welding with all types of electrodes, especially low hydrogen. The out- put CONTROL dial adjusts the full output range for stick welding.

The ARC CONTROL knob sets the short circuit cur- rent during stick welding (arc-force). Increasing the number from -10 to +10 increases the short circuit cur- rent and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is rec- ommended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with the dial set at 0.

PIPE Welding

This slope controlled setting is intended for "out-of- position" and "down hill" pipe welding where the oper- ator would like to control the current level by changing the arc length. The output CONTROL dial adjusts the full output range for pipe welding.

The ARC CONTROL knob sets the short circuit cur- rent during stick welding (arc-force). Increasing the number from -10 to +10 increases the short circuit cur- rent and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is rec- ommended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with the dial set at 0.

 

TYPICAL RANGER 305G FUEL CONSUMPTION

 

Kohler CH22

Running Time for

 

gal./hr (liters/hr)

12 gallons -(hrs.)

 

 

 

 

Low Idle - No Load

 

 

 

2400 R.P.M.

.51 (1.9)

23.5

 

 

 

 

 

High Idle - No Load

 

 

 

3700 R.P.M.

.83 (3.2)

14.5

 

 

 

 

 

DC Weld Output

 

 

 

240 Amps @ 29 Volts

1.39 (5.3)

8.6

 

 

 

 

 

DC Weld Output

 

 

 

300 Amps @ 29 Volts

1.53 (5.8)

7.8

 

 

 

 

 

Auxiliary Power

 

 

 

9,500 Watts

1.64 (6.2)

7.3

 

 

 

 

 

RANGER 305G

Page 20
Image 20
Lincoln Electric IM742-A manual Stopping, Welder Operation, Typical Ranger 305G Fuel Consumption