Lincoln Electric IM846-A TECHNICAL SPECIFICATIONS - POWER WAVE 405M, Input Ac Voltage & Dc Output

Models: IM846-A

1 42
Download 42 pages 31.1 Kb
Page 10
Image 10
TECHNICAL SPECIFICATIONS - POWER WAVE 405M

 

A-1

 

 

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 405M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

 

Product

Ordering

Input AC

Rated DC Output

Output

Weight

Dimensions

 

 

Name

Information

Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

 

 

 

 

 

 

50/60 Hz

(continuous)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350A

/ 34V / 60%

 

 

14.7”x12.5”x

 

 

Power

 

200-220/

3

Phase

 

 

27.8”*

 

 

Wave

K 2369-1

380-400/

320A / 33V / 60%

AMPS

86.5lbs

(373x318x

 

 

405M

 

415

1

Phase

5-425

(37.4 kg)

706*)mm

 

 

 

 

 

50/60 Hz

 

 

 

 

 

 

 

 

 

 

275A

/ 31V /100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Phase

 

 

 

 

 

 

 

 

 

300A / 32V / 100%

 

 

* Includes

 

 

 

 

 

 

3 Phase

 

 

handles

 

 

 

 

 

 

 

 

 

 

 

 

*Overall Length Including Handle, 21.6” (549mm) without handle. Insulation Class 180 (H)

POWER WAVE 405M INPUT CURRENT

Recommended Fuse Sizes based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

 

Output

 

Recommended

 

 

Voltage

Phases

300Amps@

350Amps@

Line Cord

Size Fuse Size

Notes

 

 

32Volts(100%)

34Volts(60%)

AWG SIzES

 

 

 

200

3

41

48

6

80A

Note 2

220

3

37

48

6

80A

Note 2

380

3

23

28

8

50A

 

 

400

3

22

27

8

50A

 

 

415

3

22

26

8

50A

 

 

Voltage

Phases

275Amps@

320Amps@

Line Cord

Size Fuse Size

Notes

 

 

31Volts(100%)

33Volts(60%)

 

 

 

200

1

----

----

---

-----

Note 1

220

1

64

82

4

125A

Note 2

380

1

44

55

6

80A

Note 2

400

1

40

50

8

80A

 

415

1

38

48

8

80A

 

 

 

 

 

 

 

 

1.Not rated is indicated by 4-x's in the box on the rating plate

2.When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CAbLES, CONNECTIONS AND LIMITATIONS

Select the output cable size based upon the following chart.

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:

 

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

 

 

100%

275

1/0

1/0

 

 

60%

350

1/0

2/0

 

POWER WAVE 405M

Page 10
Image 10
Lincoln Electric IM846-A manual TECHNICAL SPECIFICATIONS - POWER WAVE 405M, Input Ac Voltage & Dc Output, Product, Ordering