ERROR CODES FOR THE POWERWAVE

The following is a list of possible error codes that the POWER WAVE 405M can output via the status light (see "Troubleshooting the Power Wave / Power Feed System Using the Status LED." If connected to a PF-10/11 these error codes will generally be accompanied by an "Err 006" or "Err 100" on the user interface display.

 

Error Code #

Indication

11

CAN communication bus off.

Probably due to excessive number of communication errors.

12

User Interface time out error.

UI is no longer responding to the Power Source. The most likely

 

 

cause is a fault/bad connection in the communication leads or con-

 

 

trol cable.

 

 

 

21

Unprogrammed Weld Mode.

Contact the Service Department for instructions on reloading the

 

 

Welding Software.

22

Empty Weld Table.

Contact the Service Department for instructions on reloading the

 

 

Welding Software.

23

Weld Table checksum error.

Contact the Service Department for instructions on reloading the

 

 

Welding Software.

31

Primary overcurrent error.

Excessive Primary current present. May be related to a short in the

 

 

main transformer or output rectifier.

32

Capacitor "A" under voltage

Low voltage on the main capacitors. May be caused by improper

 

 

input configuration.

33

Capacitor "B" under voltage

When accompanied by an overvoltage error on the same side, it

 

 

indicates no capacitor voltage present on that side, and is usually

 

 

the result of an open or short in the primary side of the machine.

34

Capacitor "A" over voltage

Excess voltage on the main capacitors. May be caused by improp-

 

 

er input configuration.

 

 

 

35

Capacitor "B" over voltage

When accompanied by an under voltage error on the same side, it

 

 

indicates no capacitor voltage present on that side, and is usually

 

 

the result of an open or short in the primary side of the machine.

 

 

 

36

Thermal error

Indicates over temperature. Usually accompanied by Thermal LED.

Check fan operation. Be sure process does not exceed duty cycle

 

 

 

 

limit of the machine.

 

 

 

37

Soft start error

Capacitor precharge failed. Usually accompanied by codes 32-35.

 

 

41

Secondary overcurrent error

The secondary (weld) current limit has been exceeded. When this

occurs the machine output will phase back to 100 amps, typically

 

 

 

 

resulting in a condition referred to as "noodle welding"

 

 

NOTE: The secondary limit is 570 amps for the standard stud, and

 

 

325 amps for all single phase operation.

 

 

 

43

Capacitor delta error

The maximum voltage difference between the main capacitors has

 

 

been exceeded. May be accompanied by errors 32-35.

 

 

 

Other See Power Wave Diagnostic Software.

Error codes that contain three or four digits are defined as fatal

errors. These codes generally indicate internal errors on the

The Service Navigator has additional and later Error Codes listed in

the diagnostic Utility Software.

Control Board. If cycling the input power on the machine does not

clear the error, try reloading the operating system. If this fails,

Also similar information can be found on Web site at

replace the control board.

www.powerwavesoftware.com.

 

 

 

 

ERROR CODES FOR THE POWERWAVECAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE 405M