OUTPUT PANEL CONTROLS

B-2

OPERATION

B-2

OUTPUT PANEL CONTROLS

Physical Location of Components may vary by Code No.

FIGURE B.1 (For Codes 11182, 11187, 11215)

FIGURE B.2 (For Codes 11403, 11404)

9

 

1

9

 

 

1

 

 

POWER ARC 555 000

70

80

 

POWER ARC 5500

 

80

 

AMPS

 

 

70

 

AMPS

 

 

 

AMPS

 

 

 

 

 

AMPS

 

 

 

 

 

 

125

 

 

125

 

90

8

90

 

AMPS

 

AMPS

AMPS

 

GENERATOR

 

 

GENERATOR

AMPS

 

100

 

 

100

 

 

AMPS

 

 

 

AMPS

 

 

 

 

 

WARNING

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

8

2

 

 

6

 

 

 

 

 

2

 

 

ELECTRODE SELECTION GUIDE

7

ELECTRODE SELECTION GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

4

5

 

 

 

 

 

6

 

 

4

5

3

 

3

 

 

 

 

 

 

 

 

 

 

1.CURRENT CONTROL DIAL

2.ELECTRODE SELECTION GUIDE

3.WELD OUTPUT TERMINAL (TO ELECTRODE HOLDER) WITH 1/2 - 13 FLANGE NUT

4.WELD OUTPUT TERMINAL (TO WORK) WITH 1/2 - 13

FLANGE NUT

5.GROUND STUD

6.20 AMP CIRCUIT BREAKERS (2)

7.20 AMP, 240 VOLT RECEPTACLE

8.20 AMP, 120 VOLT DUPLEX RECEPTACLE

9.TACHOMETER / HOURMETER (CODE 11215 ONLY)

1.CURRENT CONTROL DIAL

2.ELECTRODE SELECTION GUIDE

3.WELD OUTPUT TERMINAL (TO ELECTRODE HOLDER) WITH 1/2 - 13 FLANGE NUT

4.WELD OUTPUT TERMINAL (TO WORK) WITH 1/2 - 13

FLANGE NUT

5.GROUND STUD

6.20 AMP CIRCUIT BREAKER

7.20 AMP, 240 VOLT RECEPTACLE

8.20 AMP, 120 VOLT DUPLEX RECEPTACLE

9.TACHOMETER / HOURMETER (CODE 11404 ONLY)

LIMITATIONS

The POWER-ARC 5500 is not recommended for any processes besides those that are normally per- formed using stick welding (SMAW) procedures.

The POWER-ARC 5500 is not recommended for pipe thawing.

During welding, generator power is limited to 100 watts, and output voltages can drop from 120 to 80 volts and 240 to 160 volts. Therefore, DO NOT OPERATE ANY SENSITIVE ELECTRICAL EQUIP- MENT WHILE YOU ARE WELDING.

CONTROLS AND SETTINGS

All generator/welder controls are located on the Output Control Panel. Gasoline engine controls are mounted on the engine. See Figures B.1 and B.2 and the explanations that follow.

GENERATOR/WELDER CONTROLS

See Figure B.1 for the location of the following fea- tures:

1.CURRENT CONTROL DIAL: Adjusts continuous current output. The amperages on the dial corre- spond to the average amperages needed for spe- cific Lincoln welding electrodes.

2.ELECTRODE SELECTION GUIDE: Provides rec- ommended electrode type, size, and welder out- put setting based on the thickness of the work.

3.WELD OUTPUT TERMINAL (TO ELECTRODE HOLDER) WITH 1/2 - 13 FLANGE NUT: Provides the connection point for either the electrode hold- er or the work cable. (Because the POWER-ARC 5500 is an AC output machine, either output ter- minal can be used for either cable.)

POWER-ARC 5500