Lincoln Electric IM871-A Operation, TABLE B.3, Generator Power Applications, Running Watts, Surge

Models: IM871-A

1 50
Download 50 pages 59.67 Kb
Page 21
Image 21
TABLE B.3

B-6

OPERATION

 

 

B-6

 

 

 

TABLE B.3

 

 

 

 

 

GENERATOR POWER APPLICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

Suggested Power Applications

 

Running Watts

*Start-up Watts

 

 

 

 

 

(Continuous)

(Surge)

 

 

 

 

 

 

 

 

 

 

 

*Air Compressor - 1 HP

 

2,000

4,000 - 8,000

 

 

 

 

*Air Compressor - 3/4 HP

 

1,250

3,100 - 5,000

 

 

 

 

*Airless Sprayer - 1/3 HP

 

600

1,500 - 2,400

 

 

 

 

Chain Saw

 

1,200

 

 

 

 

 

Circular Saw

 

1,200

 

 

 

 

 

Coffee Maker

 

1,000

 

 

 

 

 

*Deep Freezer

 

500

750 - 2,000

 

 

 

 

*Electric Motor - 1 HP

 

1,000

2,500 - 4,000

 

 

 

 

Electric Range (1 element)

 

1,500

 

 

 

 

 

Electric Skillet

 

1,250

 

 

 

 

 

*Furnace Fan - 1/3 HP

 

1,200

3,000 - 4,800

 

 

 

 

Portable Grinder (4 1/2”)

 

600

 

 

 

 

 

Portable Grinder (7”)

 

2,000

 

 

 

 

 

Halogen Work Light

 

500

 

 

 

 

 

Hand Drill - 1/4”

 

500

 

 

 

 

 

Hand Drill - 3/8”

 

700

 

 

 

 

 

1500 Watt Heater

 

1,750

 

 

 

 

 

Hedge Trimmer

 

450

 

 

 

 

 

Light Bulb

 

100

 

 

 

 

 

Reciprocating Saw

 

900

 

 

 

 

 

Radial Arm Saw

 

2,600

 

 

 

 

 

Radio

 

50

 

 

 

 

 

*Refrigerator/Freezer (small)

 

600

1,500 - 2,400

 

 

 

 

Slow Cooker

 

200

 

 

 

 

 

*Submersible Pump - 1 HP

 

1,000

2,500 - 4,000

 

 

 

 

*Sump Pump

 

600

1,500 - 2,400

 

 

 

 

Toaster

 

1,100

 

 

 

 

 

Weed Trimmer

 

500

 

 

 

 

 

Lincoln Wire Feeder/Welder

 

4,000

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Wattages listed are approximate. Check your equipment for actual wattage.

Equipment with unusually high *START-UP WATTS are listed. For start-up of other tabled equipment that uses a motor, allow up to 2 times the running watts shown above. For example a 1 HP motor requires approximately 1000 watts of power when running but may require (2.5 X 1000) = 2500 watts or (4.0 X 1000) = 4000 watts to start.

Multiple loads can be used as long as the total load does not exceed 5,500 surge watts or 4,000 continuous watts. Be certain to start the largest loads first.

Output rating in watts is equivalent to volt-amperes at unity power factor (resistive load) and is calculated as: WATTS = VOLTS X AMPS DRAWN. for example a 120 volt device which is rated on its nameplate to draw 2 amps will need (120 VOLTS) X (2 AMPS) = 240 WATTS OF POWER. 1 KW = 1000 WATTS.

POWER-ARC 5500

Page 21
Image 21
Lincoln Electric IM871-A Operation, TABLE B.3, Generator Power Applications, Suggested Power Applications, Running Watts