![](/images/new-backgrounds/1107235/107235155x1.webp)
Modem Configuration
This page allows you to configure the | LINDY MC5 | |
COM1 serial port located at the rear of | Modem Config |
|
the | Server IP | 192.168.3.1 |
| Client IP | 192.168.3.2 |
Server IP / Client IP | Baud Rate | 115200 |
When a user dials into the | InitString | ATZS0=1 |
via a modem or ISDN adapter, the |
|
|
Initialize Port |
| |
device network using PPP (Point to |
| |
Restore Defaults |
| |
Point Protocol). For this purpose, |
|
|
both devices must have ‘dummy’ | ||
IP addresses so that they can | ||
communicate correctly. These two | ||
|
|
addresses can be almost anything
expressed in the quad octet format (i.e. 192.168.3.1.). However, it is advisable not to make them the same as the real IP addresses used by either the remote system or the MC5.
Baud Rate
This option configures the speed of the serial connection between the MC5- IP and a connected modem or ISDN terminal adapter. The default setting is 115200. The other communication settings are fixed as: No parity, 8 bit word, 1 stop bit.
Init String
The codes entered here are used to prepare the connected modem or ISDN terminal adapter for use with the
Initialize Port
When selected, this option sends the characters entered in the ‘Init string’ field to the connected modem or ISDN terminal adapter.
Restore Defaults
When selected, this option resets the ‘Baud rate’ and ‘Init string’ values to their original default settings.
Reset Configuration
This option allows you to completely reset the IP portion of the
WARNING: This process will remove all network and modem/ISDN settings and return the unit to use its original state. A complete reconfiguration will be required before the IP features of the unit can be used.
To reset the MC5-IP configuration
1 With the Reset Configuration option highlighted, press .
2Access the Configure IP port option to view the initial IP configuration screens. See Initial IP configuration for details.
77