Relay Output Wiring
Any of the four relay outputs channels
Door or Pedestrian Gate Control
1. | Install a low voltage electric door strike or magnetic lock as a |
| locking device for the door or pedestrian gate. |
2. | Install the power supply or transformer for the locking device. DO |
| NOT POWER THE |
3. | Connect one wire from the power supply to one wire from the |
| locking device. |
TYPICAL DOOR STRIKE HOOKUP
ELECTRIC
DOOR
STRIKE
DOOR
STRIKE
POWER SUPPLY
RELAY
TERMINALS
N.C.
COM
N.O.
DS
GND
RTE
4. Route two wires between the locking device and the |
Connect one wire to the remaining wire of the locking device. |
Connect the other wire to the remaining wire of the power supply. |
5A. For a door strike, connect the wires to the
5B. For a magnetic lock, connect the wires to the
Gate Control
1.Route two wires between the gate and the
2.Connect the gate operator’s OPEN terminals to the
✦NOTE: For operator wiring specifics, refer to the gate operator’s wiring diagram.
Request-to-Exit Inputs
Each of the four relay outputs has a
TYPICAL MAGNETIC LOCK HOOKUP
MAGNETIC | N.C. | |
DOOR | ||
COM | ||
LOCK | ||
N.O. | ||
| ||
DOOR | DS | |
LOCK | GND | |
POWER SUPPLY | RTE | |
TYPICAL AUTOMATIC GATE HOOKUP | ||
OPERATOR OPEN | N.C. | |
N.O. | ||
GATE | COM | |
| DS | |
RELAY RATING: | GND | |
3 AMPS @ 30 VOLTS | RTE | |
AC/DC MAXIMUM |
|
1.Install the pushbutton or device to signal an exit request.
2.Route two wires from the device to the
3.Connect the device’s normally open output to the wires.
4.To activate a relay channel, connect the wires to the associated relay
Sensing Inputs
The sensing inputs can connect to a door switch that monitors whether the controlled door is open or closed.
1.To use the door sense feature to detect forced entry or door ajar conditions, install a normally closed door switch on the door
or pedestrian gate and route two wires from the switch to the
2.Connect the sensing device wires to the associated relay sensing terminal
NOTE: DOOR SENSE CONTACT
IS NORMALLY CLOSED
DOOR
SENSE
CONTACT
DOOR EXIT
REQUEST
BUTTON
OR
GATE
EXIT LOOP
SENSOR
N.C.
COM
N.O.
DS
GND
RTE
RELAY
TERMINALS
DS = SENSING INPUT
RTE =
NOTE: DOOR EXIT REQUEST BUTTON AND GATE EXIT LOOP CONTACT ARE NORMALLY OPEN