Power Supply Rough-In

TE6D Power Supply

The Power Supply unit is pre-wired and self contained, and the wires are tucked inside. To access connection wires, open the Power Supply unit by removing four screws as shown in Figure 6. In the unlikely case that the TE6D electrical connectors become unplugged, the 3-pin and 6-pin connector blocks can be re-installed in their respective locations on the power supply board. Plug connectors in as shown.

WARNING

ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE TE6D POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES

Power Supply Connections

The 6-pin connector is the low voltage (13.8 VDC, 3.8 amp) output from theTE6D Power Supply unit:

Position 3 is the Black Negative connection for the Master Station

Position 5 is the Red Positive connection for the Master Station

The 3-pin connector is for the 110/120 High Voltage input:

Black wire is position 1

White wire is position 3

PRE-WIRED SELF CONTAINED TE6D POWER SUPPLY

 

BOTTOM HOUSING

REMOVE 4 SCREWS

TOP HOUSING

TO ACCESS POWER

 

SUPPLY WIRES

 

3-PIN

3

 

WHT

CONNECTOR

BOTTOM HOUSING

1

 

BLK

2

 

 

 

 

6-PIN CONNECTOR

6

5

4

3

2

1

RED

BLACK

STRAIN RELIEF

TOP HOUSING

STRAIN RELIEF

Figure 6. Opening TE6D Power Supply

13

Page 15
Image 15
Linear VMC-1 manual Power Supply Rough-In, TE6D Power Supply, Power Supply Connections