Auxiliary Output Rough-In

Door Release Rough-in

The Door Release Trigger can be activated from the VMC1 Master or any remote room station by pressing the Lock button. The Trigger will deactivate after 4 seconds and can be activated multiple times while the intercom is active.

To connect the optional Linear Model DRW Door Release Mechanism, refer to Figure 10 For controlling other door release devices, refer to the hook-up instructions supplied with the device.

1.Route a blue and a white 18 gauge wire from the Door Station location or VMC1MB to the optional 12V Model 284 relay. (See Appendix A). Following this color convention will assist in the final installation of the Door Station.

2.Connect the blue wire to the red coil wire on the 284 relay.

3.Connect the white wire to the white coil wire on the 284 relay.

4.Connect a red 18 gauge wire to the green Normally Open wire on the 284 relay.

5.Connect a red 18 gauge wire to the blue Common wire on the 284 relay.

6.Connect the other end of the red wire from the relay to the Yellow wire on the RT35 or either of the wires on the RT11.

7.Connect the other end of the red wire from the relay to one of the wires from the DRW.

8.Connect the remaining wire on the DRW to the Yellow/ Red wire on the RT35 or the remaining wire on the RT11.

9.Install the optional DRW into the door frame following the included instructions.

Chime Activated Control Output Rough-In

The Chime Activated Control Output allows for any number of security related automation functions including 10 available door chimes.To connect an auxiliary Chime refer to Figure 10. Refer to the hook-up instructions supplied with the chime.

1.Route a blue and a black 18 gauge wire from the Door Station location or VMC1VDS to the optional 12V Model 284 relay. (See Appendix). Following this color convention will assist in the final installation of the Door Station.

2.Connect the blue wire to the red coil wire on the 284 relay.

3.Connect the black wire to the white coil wire on the 284 relay.

4.Connect a red 18 gauge wire to the green Normally Open wire on the 284 relay.

5.Connect a red 18 gauge wire to the blue Common wire on the 284 relay.

6.Connect the other end of the red wire from the relay to the Yellow wire on the RT35 or either of the wires on the RT11.

7.Connect the other end of the red wire from the relay to one of the wires from the Chime.

8.Connect the remaining wire on the Chime to the Yellow/ Red wire on the RT35 or the remaining wire on the RT11.

9.Install the optional Auxiliary Chime following its instructions.

VMC1VDS

DRW

MODEL DRW

ELECTRONIC DOOR STRIKE

OR CHIME

GRAY

DOOR

N/C NORMALLY CLOSED

STATION

BLUE

 

 

COMMON

BLUE

RED

GREEN

NORMALLY OPEN

 

 

WHITE

WHITE

 

BLACK

MODEL 284

 

 

12V 5 AMP RELAY

 

USE WHITE WIRE FOR DOOR RELEASE

USE BLACK WIRE FOR AUXILIARY CONTROL OUTPUT

110VAC 24VAC

MODEL RT11 OR RT35

PLUG-IN TRANSFORMER

Figure 10. Electric Door Strike Wiring