Link electronic MC-6 owner manual Basic Troubleshooting, Condition, Cause, Remedy

Models: MC-6

1 34
Download 34 pages 38.44 Kb
Page 32
Image 32
Basic Troubleshooting

Basic Troubleshooting

A summary of fault conditions and their causes and remedies are listed below.

The MC-6 Multi-Channel Power Amplifier can produce high power levels that, without well-designed protection circuitry, could damage loudspeakers. Therefore, most fault conditions will result in the MC-6 reverting to Standby Mode.

Condition:

Cause:

Remedy:

Front panel STANDBY/POWER BUTTON does not

Light bulb defective.

Remove STNADBY/POWER BUTTON from front panel

illuminate after pressing, amplifier operates

 

and replace bulb located under button. Use

normally:

 

replacement bulb kit and instructions supplied by

 

 

your dealer.

Front panel STANDBY/POWER BUTTON lamp does not

Incorrect power connections or circuit breaker

Review Installation/Rear Panel Power Connections

illuminate after pressing and amplifier does not

positions on rear panel of amplifier.

section of Owner’s Manual.

operate normally.

 

 

 

Abnormal Operation of the MC-6 internal circuitry.

Contact your dealer immediately.

Front panel STANDBY/POWER BUTTON reverts to

Excessive sub-sonic or DC signals produced by

Repair or replace source component. Identify and

Standby Mode during listening but can be returned

source components.

correct abnormal conditions such as low frequency

to normal operation:

 

rumble and/or acoustic feedback caused by

 

 

phono playback (if applicable).

 

Severe clipping of amplifier circuitry.

Reduce volume slightly or use higher efficiency

 

 

loudspeakers.

AC MAINS CIRCUIT BREAKER switches OFF or will not

AC mains voltage too high for amplifier.

Consult your dealer immediately to have the

remain ON:

 

amplifier reconfigured for the proper AC mains

 

 

voltage.

 

Abnormal operation of amplifier internal circuitry.

Contact your dealer immediately.

50/60 Hz buzz noise in loudspeakers:

Ground loop condition created between

Use balanced system configuration if possible.

 

components in system.

 

 

 

Inspect interconnect cables for poor connection or

 

 

termination.