Lochinvar 151-286 operation manual 120 VAC, High Voltage

Models: 151-286

1 56
Download 56 pages 3.42 Kb
Page 55
Image 55

Outdoor Knight Boiler Installation & Operation Manual

10 Diagrams (continued)

Figure 10-2Wiring Diagram

 

LOW VOLTAGE

BOX DEPICTS

 

120 VAC

 

OPTIONAL ITEMS

 

HIGH VOLTAGE

BOX DEPICTS

 

 

 

 

DUAL SENSOR

 

 

SINGLE HOUSING

CONNECTION BOARD

INTEGRATED

 

CONTROL

JUNCTION

 

 

 

BOX

BOX DEPICTS

OPTIONAL

ITEMS

 

 

ALARM

1

 

 

 

BELL JUMPER

CONTACTS

2

 

 

ALARMBELL

RUN-TIME

3

 

 

CONTACTS

4

 

 

24 VAC LOUVER

5

 

 

RELAY COIL

6

 

 

LOUVER

7

CN5-1

BK

 

 

PROVING SWITCH

8

 

 

CN5-8

BK

 

 

GAS PRESSURE

9

 

 

CN5-2

BK

 

 

SWITCH

10

 

 

CN5-9

BK

 

 

 

 

 

SWITCH

 

 

 

 

CN5-3

BK

 

 

 

 

CN5-10

BK

 

 

 

 

CN5-11

BK

SILENCING

 

 

 

 

CN5-4

BK

 

FLOW

11

CN5-5

BK

 

SWITCH

12

CN5-14

BK

 

TANK

13

CN5-12

BK

 

 

THERMOSTAT

14

CN5-6

BK

 

 

HEAT/LOOP

3

15

CN5-13

BK

 

 

DEMAND

16

CN5-7

BK

 

 

HEAT/LOOP

2

17

 

 

 

 

DEMAND

18

 

 

 

 

HEAT/LOOP

 

 

 

 

X-7

X4-7

X4-14

X4-6

X4-13

X4-5

X4-12

X4-11

X4-4

X4-3

X4-8

X4-10

X4-2

X4-9

X4-1

X1-3

X1-4

X1-2

X1-6

X1-5

X1-8

X1-1

OR

BR

PR

BK

W

G

R

W

W

W

KB ONLY

ON/OFF

SWITCH

L

G

DHW

N

PUMP

 

 

 

L

G

BOILER

 

N

PUMP

 

 

 

L

G

SYSTEM

 

N

 

PUMP

 

 

L

L

120V

N

GND

SUPPLY

 

N

 

DEMAND 1

19

 

20

 

SYSTEM

 

 

21

 

SENSOR

 

 

22

 

OUTDOOR

 

 

23

 

SENSOR

 

 

24

 

 

 

 

25

 

TANK

 

 

26

 

SENSOR

 

 

27

 

 

 

 

28

 

SHIELD

 

 

29

 

A

 

 

30

 

CASCADE

 

 

31

 

B

 

 

 

SHIELD

 

 

32

 

 

 

 

 

CN6

BMS

+

0-10V

33

 

IN

-

34

 

SYS PUMP

+

0-10V

35

 

IN

-

36

 

BLR PUMP

+

0-10V

37

 

OUT

-

38

 

RATE

+

0-10V

39

 

OUT

-

40

 

SHIELD

 

41

 

MODBUS

A

 

42

 

OPTION

B

 

43

 

SHIELD

 

44

 

LOW

 

24 VAC

CN7-1

 

WATER

 

COM

CN7-2

CN8-1 CN8-2 CN8-3

 

 

CN7-3

CUT-OFF

 

 

 

 

CN7-4

 

 

 

 

R BLG

X6

TRANSFORMER

R W G

1 2 3

 

BLOWER

 

 

1 2 3 4 5

 

X5-7

R

 

X5-16

T

 

X5-8

W

 

X5-15

BK

 

X5-9

Y

 

X5-1

BL

 

X5-2

O

KB 286 ONLY

 

X5-10

BLOCKED DRAIN SWITCH

O-TEMP HEX SW

P

 

X5-11

AIR PRESSURE SWITCH

O/BK

 

X5-4

-T

 

R/BK

OPERATING SENSOR S1a

X5-12

-T

HIGH LIMIT SENSOR S1b

GY

X5-6

-T

INLET SENSOR S2

P/BK

X5-5

-T

FLUE SENSOR S3a

W/BK

X5-13

-T

FLUE SENSOR S3b

PR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X6-3

X6-2 X6-1 X6-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X2-2

 

 

BK

 

 

 

 

 

 

 

GAS VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X4-1

 

 

 

 

O

 

 

 

 

X9-1

 

X2-1

 

 

 

 

 

 

 

 

 

 

 

 

 

@24VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X4-2

 

 

 

GY

 

 

X9-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODBUS BOARD

 

 

 

 

X4-3

 

 

 

 

G

 

 

 

X9-3

 

X1-7

 

 

W/R

 

 

FLAME SENSOR

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X4-4

 

 

 

 

 

 

 

 

 

 

X9-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MTR-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR2

 

 

 

 

 

 

 

 

 

SPARK

 

 

 

 

 

 

 

 

 

 

SHIELD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROD

 

 

 

 

 

 

 

 

 

GROUNDING

 

 

 

 

 

 

 

 

 

X5-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

HIGH VOLTAGE SPARK LEAD

 

 

 

 

 

JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X1-1

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X1-2

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X1-3

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.

2.If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.

3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using

WIRING DIAGRAM

diagrams to troubleshoot unit.

LBL20127 REV E

55

Page 55
Image 55
Lochinvar 151-286 operation manual 120 VAC, High Voltage