Copper-fin II/IIE Boiler and Water Heater Service Manual

3 Troubleshooting (continued)

Table 3E Troubleshooting Chart - Fault Messages Displayed on Operator Interface

FAULT

DESCRIPTION

CORRECTIVE ACTION

 

 

 

 

- Either the optional manual reset low gas

• Reset the pressure switches.

 

pressure switch or the optional manual reset

 

 

high gas pressure switch tripped.

• Measure the supply gas pressure to determine

Gas Pressure SW

 

cause of failure. Refer to the Gas Connections

- Models 992 - 2072 (natural gas) - Automatic

Section of the Installation and Operation Manual for

(Will require a manual

Reset Low Gas is open.

detailed information concerning the gas supply.

reset once the condition

 

 

has been corrected.)

 

• Correct the supply gas pressure if necessary.

 

 

Flow Switch/

Either the flow switch or the optional low

• Check pump operation on a call for heat.

water cutoff is not making.

 

LWCO

 

• Check for closed valves or obstructions in the

(Lockout will reset

 

water piping.

automatically after

 

 

5 minutes or may be

 

• Verify system is full of water and all air has been

reset immediately once

 

purged from the system.

condition has been

 

 

corrected. Press the

 

 

RESET button on the

 

 

SMART SYSTEM display

 

 

to reset.)

 

 

 

 

 

Flame Sequence

The flame detector circuit is seeing a flame

• Check supply voltage for proper polarity.

signal while the gas valve is de-energized.

 

(Will require a manual

 

• Check that the gas valve is closed.

reset once the condition

 

 

has been corrected. Press

 

• Check external wiring for voltage feedback.

the RESET button on the

 

 

SMART SYSTEM display

 

• Check the internal wiring for bad connections.

to reset.)

 

 

 

 

• Replace main control board.

 

 

 

 

The main control board has received a call

• The control board will release the call for heat after

 

for heat too quickly after the previous call for

a set time period.

Anti-cycling

heat has ended.

• The control board will release the call for heat if the

 

 

 

 

 

outlet temperature drops too quickly.

37

Page 37
Image 37
Lochinvar 402, 2072 service manual Flow Switch, Flame Sequence, Anti-cycling

402, 2072 specifications

Lochinvar 2072,502 is an innovative and robust water-heating solution tailored for residential and commercial applications. This model represents a significant advancement in energy efficiency and performance, catering to the dynamic heating requirements of modern buildings.

One of the standout features of Lochinvar 2072,502 is its advanced thermal efficiency. With an impressive AFUE (Annual Fuel Utilization Efficiency) rating, the unit delivers exceptional heat output while minimizing energy consumption. This not only reduces utility bills for homeowners and businesses but also supports sustainability efforts by decreasing carbon footprints.

The Lochinvar 2072,502 incorporates cutting-edge technologies that set it apart in the market. It is equipped with advanced control systems that allow users to precisely manage heating outputs, ensuring optimal comfort while conserving energy. The user-friendly digital display provides real-time data, allowing for efficient monitoring and control.

Another significant characteristic of the Lochinvar 2072,502 is its robust stainless-steel construction. This feature enhances the unit's durability and longevity, ensuring reliable performance even in challenging conditions. The high-quality materials also contribute to maintaining consistent water temperatures, which is essential for both residential and commercial heating needs.

The Lochinvar 2072,502 operates silently, making it ideal for installations in areas where noise is a concern. Its compact design allows for flexible installation options, fitting seamlessly into various spaces, whether it’s a utility room, basement, or outdoor area.

Furthermore, the unit supports multiple venting options, accommodating different building architectures and layouts. This versatility makes it an ideal choice for new builds and retrofitting existing systems.

Maintenance is streamlined with the Lochinvar 2072,502, as it features a self-diagnostics system that simplifies troubleshooting. Regular service check-ups are made easier with accessible components, allowing technicians to perform maintenance tasks efficiently.

In summary, the Lochinvar 2072,502 stands out for its high efficiency, advanced technology, durability, and flexible installation options. It is an ideal choice for those seeking a reliable and technologically advanced water-heating solution that meets the challenges of contemporary heating demands while promoting energy savings and environmental responsibility.