3xLogic Vigil System Server Software - User’s Guide Doc# 08100610 Page 87
2.2.6 Clients Tab
The “Clients” tab indicates how Vigil Client connections should be handled.
Resolve Client
Name
When enabled, the IP addresses of clients
who log in remotely to the Vigil Server are
queried to find the computer name of the
remote client.
Max Network
Connections
Sets the maximum number of remote
connections allowed to access Vigil Server
at the same time.
Note: Each Live Viewer window, playback window, and settings screen takes up one or two
“connections” to the Server. A minimum setting of 20 is recommended.
Sequence Tab 2.2.7
The “Sequence” tab configures the camera display sequences for the analog output monitors. Only analog
video feeds can be added to a sequence. This is due to hardware limitations on the capture cards.
Monitor Number Selects which analog output monitor to create or modify its sequence.
Auto Start
Sequence When enabled, the sequence for the selected analog output monitor is started
automatically when Vigil Server starts.
Add Adds a new camera to the sequence with a specified dwell (display) time.
Edit Allows you to modify the dwell time of the selected camera.
Delete Removes the selected camera from the sequence
Up / Down Moves the selected camera up / down in the sequence.