Stove Installation (for qualified installers only)
17
Hearth Stove Direct Connection
NOTE:
Direct connections require installation of an airtight,
NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.
Max. 8”
Combustible Mantle
Min. 18"
Clay
Liner
Stainless steel chimney connector must Extend 1' past the
Airtight
Insulated
Remove damper or wire it open
Floor Protection |
(See the section |
"Floor Protection |
Requirements" for |
more details) |
See the section "Stove Placement Requirements" for minimum clearances required.
Figure 15
Interior or Exterior Masonry Chimney
NOTE:
This type of installation requires a UBC approved masonry connector or other method approved by the NFPA 211 standard. See Chimney Connector Requirements on page 10 for further details.
NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.
See the section "Stove Placement Requirements" for minimum clearances required.
Chimney connector sections
See the section "Floor Protection Requirements"
Clay Liner
Min. 18" clearance to ceiling
This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.
Make sure the
Figure 16