Lopi 1750 Chimney Termination Requirements, Outside Air Requirements, Slanted Roofs, Flat

Models: 1750

1 36
Download 36 pages 11.09 Kb
Page 12
Image 12
Chimney Termination Requirements

12

Stove Installation (for qualified installers only)

Chimney Termination Requirements

Must have an approved cap (to prevent water from entering)

Must not be located where it will become plugged by snow or other material

Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see Figure 6)

Slanted Roofs

Chimney must extend 3' above the roof

Flat

Chimney must extend 3' above the roof

Chimney must extend 2' above any portion of the roof within 10' of the chimney

Chimney must extend 2' above any portion of the roof within 10' of the chimney

Figure 6

Outside Air Requirements

Required for mobile homes & in certain localities (check with building officials)

Must not be drawn from an enclosed space (garage, unventilated crawl space)

Requires the optional outside air connector or pedestal.

Pedestal may be used to direct air from below the stove. See the pedestal instructions for complete details

When using outside air, find a location where the chimney and outside air hole do not interfere with structural members of the home.

The pedestal has an air opening for use with the outside air connections. This allows air to be drawn from behind the pedestal

Air may be drawn from a ventilated crawl space or use an air duct.

Outside Air

Connector

Outside air entrance must be placed so it does not become blocked by snow.

Figure 7

© Travis Industries

100-01179

4060926