Lopi Freedom Bay Fireplace Insert Minimum Clearances, Insert Placement Requirements, 100-01163

Models: Freedom Bay Fireplace Insert

1 32
Download 32 pages 47.97 Kb
Page 9
Image 9
Insert Placement Requirements

Installation (for qualified installers only)

9

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the insert

Insert and hearth must be installed on a level, secure floor

The minimum clearances, facing, and hearth requirements in Figure 3 must be met.

Measure side clearances from

the side of the insert.

Side Wall

 

 

e

Mantel

 

Minimum Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustibl

 

 

k

Sidewall to Insert

15"

 

 

Combustible

 

l

Side Facing

13-1/2"

 

n

Top

m

Top Facing

30"

 

 

 

 

 

 

 

Facing

with mantel shield

17"

 

 

 

 

 

 

 

 

 

 

 

 

 

m

 

n

Mantel to Insert

32"

 

 

 

Facing

with mantel shield

19"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

o

Hearth (Front)

16"

k

 

 

 

 

p

Hearth (Side)

8"

l

 

 

 

q

 

 

 

 

 

 

Front of Insert

36"

 

p

 

 

 

 

 

 

 

Non-

 

 

 

x

Extension onto Hearth

4-3/4"

q

HearthCombustible

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

 

 

 

Measure front clearances from

the faceplate.

Figure 3

Hearth Requirements

Must extend 16" in front of the insert and 8" on both sides

Must be non-combustible and at least .018" thick (26 gauge)

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)

Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired prior to installation of the insert

Chimney height: 15' minimum; 33' maximum.

Entire fireplace, including chimney, must meet local building requirements

© Travis Industries

100-01163

4041129

Page 9
Image 9
Lopi Freedom Bay Fireplace Insert Minimum Clearances, Insert Placement Requirements, Hearth Requirements, 100-01163