6 | Features & Specifications |
Installation Options:
•Masonry Fireplace Insert
WARNING: Do not install this fireplace insert into a
Features:
•EPA Phase II Approved
•2.9 Cubic Foot Firebox Volume
•Single Operating Control
•Accepts Logs Up to 24" Long
•Steel Plate Construction (5/16" & 3/16")
•Heavy Duty Refractory Firebrick
•Optional
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* | 1,200 to 2,250 | (Extended) |
| 1,200 to 2,000 | (with Flush Kit) |
Maximum BTU's per Hour (Cord Wood Calculation) | 73,300 |
|
Overall Efficiency (Oregon Method) | 71.1 % |
|
Maximum Burn Time | Up to 12 Hours |
*Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions:
Measure side and top clearances from the top plate.
7"
Fireplace Opening -
Extended Position (stock)
Weight = 455 lbs.
Emissions:
Fireplace Opening -
Flush Position (requires kit)
Figure 1
3.2 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C.