Louisville Tin and Stove DVCF403B-R warranty Terminal Block Wiring Diagram, Manual Reset Switch

Models: DVCF557B-R DVCF653B-R DVCF654B-R DVCF403B-R DVCF408B-R DVCF558B-R DVCF404B-R DVCF407B-R

1 22
Download 22 pages 34.74 Kb
Page 13
Image 13
TERMINAL BLOCK WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

TERMINAL BLOCK WIRING DIAGRAM

 

Fan/Limit Switch (Brown)

 

 

Fan/Limit Switch (Brown)

Selector Switch

Power Cord (Black)

 

 

Power Cord (Black)

(Red)

Transformer (Black)

 

 

Transformer (Black)

Motor

Limit

 

 

Limit

Switch

 

 

Switch

(Red)

(Blue)

 

 

(Blue)

MOTOR (White)

 

MOTOR (White)

Power Cord

Selector

 

Power Cord

Fan

Switch

 

Switch

(Green)

(Black)

 

(Green)

(Black)

Terminal Board

Motor (Black)

 

Terminal Board

Motor (Black)

Ground (Green)

Transformer (Black)

 

Ground (Green)

Transformer (Black)

Motor

 

Motor

 

 

Power Cord (White)

(Green)

Power Cord (White)

 

(Green)

 

P/N 91123

 

 

P/N 91122

DVCF557B, 558B, 653B, 654B

 

DVCF403B, 404B, 407B, 408B

MANUAL RESET SWITCH

For your safety this furnace is equipped with a manual reset limit switch. In case of failure by the primary limit switch, this switch will shut the valve down completely before unsafe temperatures are reached. After a cool down period, switch must be manually reset. If outages persist, call a qualified service person.

MAINTENANCE INSTRUCTION

For proper and safe operation, keep furnace and furnace area clean. At regular intervals turn control valve off, let cool and clean inside control compartment. To clean cabinet, use only a damp cloth. Do not use any kind of solvent or cleaning fluid that could leave a residue or invisible coating that would burn or give off fumes when furnace is turned on.

Have the furnace checked, cleaned, and repaired by a qualified service person for vent system, pilot and burner operation prior to use each year.

The bearings of the fan motor should be oiled every twelve (12) months with S.A.E. 20 oil. (See Figure 10).

Follow a regular service and maintenance schedule for safe and efficient operation.

Examine the venting system as a routine part of the safety performance check on an annual basis.