LOCATIONS

1.This furnace must be installed on an outside wall and vented to the outside. If possible, this wall should be on the side of the house that receives the least amount of wind since strong gusting winds could cause pilot outage.

2.For most efficient performance, locate furnace as centrally as possible in the area to be heated.

3.The furnace can be installed flush against a wall or recessed up to 10” maximum. For proper combustion, make sure unit is level front to back and side-to-side.

4.Do not install the furnace in a closet, alcove or small hallway where the furnace could be isolated from the space to be heated by closing a door.

5.Be sure the vent cap will have the proper clearances (See Figure 2).

6.Check inside the wall to make sure there are no obstacles such as water pipes, electric wiring, etc. which could interfere with the installation of the furnace or vent tubes.

7.Be sure to maintain adequate accessibility clearances for servicing and proper operation.

8.If the furnace is installed in a basement, a 12” clearance must be maintained between ground level and the bottom of the vent cap. Do not install furnace where vent cap will terminate in a window well or any other opening below ground level.

INSTALLATION

ELECTRICAL ROUGH-IN

For convenience, this furnace is equipped with a three-prong power cord located on the top left of heater. The 115V wiring should be brought in on the left side terminating in a receptacle box (not provided). Consult local codes or ordinances. (For Amps, see Page 2/Specifications and Dimensions).

ROUGH-IN GAS SUPPLY

Install a 1/2 inch diameter gas supply line. The gas line can enter the cabinet through the right side or bottom (See Figure 3). The gas line must have an individual manual shut off valve. Also, you must install a drip leg and provide a 1/8” N.P.T. plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the furnace (See Figure 4).

The furnace and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.5kPa). The furnace must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa).

 

 

 

3-1/2”

 

 

 

2-5/8”

 

 

 

1-1/2 OA

 

 

 

 

FIGURE 3

 

 

 

 

 

 

 

 

Gas

 

 

 

Supply

Drip

 

Line

Manual

1/8 N.P.T.

Leg

Cut Off

Pressure Tap

 

 

Valve

FIGURE 4

 

 

 

 

 

9-1/4

 

 

DIA.

 

 

WALL

 

DVCF40 - 59”

STUDS

 

DVCF55/65 - 68-1/2”

 

 

 

 

FINISHED

 

 

FLOOR

 

 

 

FIGURE 5

 

 

Page 6

Page 6
Image 6
Louisville Tin and Stove DVCF408B-R Locations, Installation Electrical ROUGH-IN, ROUGH-IN GAS Supply, DIA Wall, Studs

DVCF557B-R, DVCF653B-R, DVCF654B-R, DVCF403B-R, DVCF408B-R specifications

The Louisville Tin and Stove DVCF series offers a range of innovative and versatile vented gas fireplaces, designed to enhance the aesthetic appeal and comfort of any space. Key models in this series include the DVCF404B-R, DVCF654B-R, DVCF653B-R, DVCF557B-R, and DVCF407B-R. Each fireplace is engineered with advanced features and technologies, ensuring an efficient and enjoyable heating experience.

The DVCF404B-R is a compact yet powerful model, perfect for smaller areas. It delivers a heat output of up to 30,000 BTUs, providing ample warmth while maintaining energy efficiency. Its sleek design and modern appearance make it an attractive focal point in any room. The DVCF654B-R, on the other hand, boasts a larger heating capacity, ideal for more spacious environments. With BTUs reaching 38,000, this fireplace ensures that larger areas remain comfortably warm even during harsh winter months.

The DVCF653B-R combines functionality with elegance, featuring a contemporary linear design that fits well into various interior styles. Its advanced venting technology ensures easy installation and optimal performance, allowing homeowners to enjoy the flames' beauty without compromising on safety or efficiency. Meanwhile, the DVCF557B-R is particularly noteworthy for its customizable options, which enable users to choose from various finishes and decorative media, personalizing their fireplace to match their unique tastes.

Lastly, the DVCF407B-R offers a blend of traditional and modern aesthetics, making it a versatile choice for different decor styles. Its efficient heating capabilities and advanced safety features, such as automatic shut-off and a glass front for reduced emissions, make it a reliable option for families.

Overall, the Louisville Tin and Stove DVCF series not only enhances home decor but also prioritizes efficiency, safety, and ease of use. Each model embodies quality craftsmanship and modern technological advancements, making them exceptional choices for anyone looking to invest in a gas fireplace. The comprehensive features, from customizable designs to high BTU outputs, make the DVCF series a standout in the market for homeowners seeking comfort and style.