. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements

Environmental Requirements

The array modules are designed to operate in the environment defined in Table 4-4and Table 4-5 on page 4-7.

Table 4-4 Array Module Environmental Requirements

Condition

Parameter

Requirement

 

E2400 10x and E2400 14x

 

 

 

 

 

 

Operating Range

10° C to 40° C (50° F to 104° F)

 

Maximum Rate of Change

10° C (18° F) per hour

Temperature

Storage Range

-10°C to 50° C (14° F to 122° F)

Maximum Rate of Change

15° C (27° F) per hour

 

 

Transit Range

-40°C to 60° C (-40°F to 140° F)

 

Maximum Rate of Change

20° C (36° F) per hour

 

Operating Range

20% to 80%

 

 

 

 

Storage Range

10% to 90%

Relative Humidity

 

 

Transit Range

5% to 95%

No condensation

 

 

 

Maximum Dew Point

26° C (79° F)

 

Maximum Gradient

10% per hour

 

 

 

Sound

Sound Power

6.0 bels

 

 

Sound Pressure

60 dBA

 

 

 

 

Altitude

Operating and Storage

3000 m (9840 ft.)

(Above Sea Level)1

 

 

Transit

12,000 m (40,000 ft.)

 

 

 

Altitude

Operating, Storage,

30.5 m (100 ft.)

(Below Sea Level)

and Transit

 

 

 

 

1 If you plan to operate an array module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level, lower the environmental temperature 1.7° C (3.3° F) for every 1000 m (3280 ft.) above sea level.

Table 4-5 Array Module Heat Dissipation

Model

Low Profile (LP)

Half Height (HH)

18 GB and 36 GB Drives

36 GB and 73 GB Drives

 

 

 

 

E2400 10x

1187 Btu/hr (0.35 kVA or 347 W)

1221 Btu/hr (0.37 kVA or 357 W)

 

 

 

E2400 14x

1118 Btu/hr (0.328 kVA or 327 W)

Not applicable.

 

 

 