5.0 OPERATION
Once the Model 1088 is properly configured and installed, it should oper- ate transparently. This sections describes
5.1 POWER-UP
To apply power to the Model 1088, first be sure that you have read sec- tion 4.3, “Connect
5.2 LED STATUS MONITORS
The Model 1088 features six front panel LEDs that monitor power, the DTE signals, network connection and test modes. Figure 10 shows the front panel location of each LED. Following Figure 10 is a description of each LEDs function. See also APPENDIX E.
| Figure 10. Model 1088/K Front Panel |
DSL LInk | (Active Green) Solid green (On) indicates that the |
| end to end DSL Framer Link is up, signifying that |
| the link across the DSL span is active. The DSL |
| Link LED is Off when the link is down. |
E1/FE1 | (Active Green) Solid green (On) indicates a valid |
Link | E1 connection. |
LOS | (Active Red) The Loss of Sync indicates that the |
| unit has lost synchronization with the incoming sig- |
| nal. This may happen when there is a framing mis- |
| match or a loss of signal. In unframed mode, the |
| LOS LED monitors the status of the transmit clock. |
NS | (Active Red) The No Signal LED glows red to indi- |
| cate that the local Model 1088 is not connected |
| with the remote Model 1088. |
18