Using the SERIAL

The projector is equipped with an RS-232C standard serial terminal at the rear. It is therefore possible to connect it to a computer for control.

Connection

• Single

Side interface panel

D-sub 9-pin (female)

SERIAL

PC

 

Unit 1 interface panel

• Plural

D-sub 9-pin

D-sub 9-pin

 

(female)

(male)

PC

IN

OUT

 

 

 

SERIAL

Unit 2 interface panel

D-sub 9-pin

D-sub 9-pin

(female)

(male)

IN

OUT

SERIAL

D-sub 9-pin (male)

D-sub 9-pin

D-sub 9-pin

(male)

(female)

D-sub 9-pin (male)

Communication cable

Communication cable

Communication cable

Pin assignments and signal names

D-Sub 9-pin (female) external appearance

Pin No. Signal name

Description

 

NC

TXD

Send data

RXD

Receive data

 

Connected internally

GND

Ground

 

NC

CTS

Connected

RTS

internally

 

NC

D-Sub 9-pin (male) external appearance

Pin No. Signal name

Description

 

NC

RXD

Receive data

TXD

Send data

 

NC

GND

Ground

 

NC

RTS

Connected

CTS

internally

 

NC

ENGLISH

 

Communication

 

 

 

Signal level

RS-232C

 

 

 

 

requirements

Sync method

Start-stop transmission

 

 

 

 

 

 

Baud rate

9 600 bps

 

 

 

Parity

None

 

 

 

Character length

8 bit

 

 

 

Stop bit

1 bit

 

 

 

X parameter

None

 

 

 

S parameter

None

 

 

 

 

 

 

Basic format

Transmission from the computer begins with STX, then the command, parameter and ETX are sent in this order. Colon (:) is not required when transmitting the command which does not need a parameter.

STX

Start

Caution

AD

 

 

I 1

I 2

 

:

 

C1

C2

C3

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID

characters

 

 

 

 

 

 

 

 

 

 

 

 

(2 Bytes)

Colon

 

 

 

 

Colon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command 3 characters

 

 

 

 

 

 

 

 

 

 

 

00 to 99

 

 

 

 

(3 Bytes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID designate

P1

P2

P3

P4

P5

 

 

 

 

 

Parameter

(1 to 5 Bytes)

ETX

End

On commencement of lamp lighting, commands cannot be sent or responses received for approximately 10 seconds. Be sure to send any commands and receive responses 10 seconds. (Applies to the PT-L6600E / PT-L6600EL only)

When transmitting several commands, wait for a response from the projector before sending the next command. When sending commands without parameters, a colon is not necessary.

When it is unnecessary to designate an ID code, send the format without the part to ID designate it.

Note

If a wrong command is received, the projector sends ER401 back to the computer.

When using control from the remote terminal, commands cannot be received at the serial terminal.

Projector ID supported on the RS-232C interface is 0 (ALL) to 99.

The remote control ID is set from 0 to 3. If a command is sent with a projector ID specified, the projector will return answer back only if the ID contained in the command matches the projector ID or the projector ID is set to ALL.

37