Lucent Technologies 03.0.042.2 Under some conditions, call record exhaustion occurred, Definity

Models: 03.0.042.2

1 16
Download 16 pages 60.75 Kb
Page 10
Image 10
31.Under some conditions, call record exhaustion occurred.

Change Descriptions

30.Tandem trunk calls that received an ALERT followed by a DISCONNECT that had a progress indicator IE did not send a CONNECT message back to the orginator before the DISCONNECT, even though the incoming trunk was administered to do so.

31.Under some conditions, call record exhaustion occurred.

32.When the Long Hold Recall feature was active and a Digital Communications Protocol (DCP) station had the “Active Station Ringing” field set to ‘silence’, and the station put a call on hold, when the long hold recall timer expired, the station received a continuous audible ring.

33.Systems with a CLAN in an Expansion Port Network (EPN) occasionally found that calls were denied for a theoretical lack of bandwidth. Socket bandwidths are now more accurately represented, resulting in no more denials unless bandwidth is actually in short supply.

34.If Path Replacement happened to remove a network loop, the display on a station could change to just a trunk group.

35.With Centralized Voice Mail via Interswitch Mode Code, if an incoming call from the PSTN to a station on the Legend covered to the voice mail on the DEFINITY, the caller received the wrong greeting ("press *H"), because the Legend was not sending the CPN IE in the SETUP message to the

DEFINITY.

36.If TN802 was in the Prologix cabinet in slot 7 and there was another board in slot 5, there was a conflict alarm generated against the reserved slot in slot 5. Slot 5 can now have any board when slot 7 contains the TN802, and no alarm is generated. The "list configuration" and "change circuit-pack" commands properly show only one reserved slot (slot 6) in this configuration.

37.Calls answered via call pickup were not correctly dropped when the originator dropped.

38.Users that put bridged calls on hold on a coverage module and then attempted to conference or transfer the call could put the station in a state that prevented using the conference or transfer buttons again until the set was busied and released during maintenance.

39.When a party dialed itself and redirected to a coverage point that was also itself, the switch reset. Now, the call will be dropped and the calling party will receive re-order or intercept tone.

40.If a party on a call activated an autodial button to dial some digits, the listen-only service observer did not hear the DTMF digits.

41.Moving agents from one split to another via CMS could cause the switch to reset.

42.Occasionally, when making an IP SoftPhone call, if the caller did not send a digit to the switch after off-hook, the switch kept the call up indefinitely, rather than timing out.

8 Release 8, Issue 3.0 (03.0.042.2)

Page 10
Image 10
Lucent Technologies 03.0.042.2 Under some conditions, call record exhaustion occurred, Definity, Release 8, Issue 3.0