Change Descriptions
The following problems have been addressed and corrected in DEFINITY Enterprise Communications Server (ECS), Release 8, Issue 3.0 (03.0.042.2).
1.When switching between PPP and X.25 type data modules, two copies of the Establish Connection field on the data module form appeared.
2.If Music on Hold for the class of restriction for an analog station was set to "no" and that station was bridged to a digital station, the analog station was blocked from flashing to transfer or conference a call.
3.
4.The system could go into overload if a sufficiently large number of calls were executing a poorly written vector (i.e., a vector with a loop not containing a wait step). Time breaks will be inserted in vector processing more frequently now, when the system experiences high processor occupancy.
5.Basic Rate Interface (BRI) trunks failed to make an outgoing call, if the network did not allocate a Terminal Endpoint Identifier (TEI) on the previous outgoing call attempt.
6.When selecting “help” in the AUDIX Name or Messaging Server Name fields on the hunt group form, the help message directed the user to a form which was no longer supported. This occurred if no “audix” or “msa” nodes were specified on the
7.Attendent Direct Extension Selection (DXS) access failed if the ARS shortcut was enabled.
Issue 1 July 2000 5