Lucent Technologies Release 3 manual Figure A-4. Voice Equipment Screen

Models: Release 3

1 98
Download 98 pages 56.97 Kb
Page 67
Image 67

Verify Channel State

Channels are usually shipped from the factory in the facility-out-of-service (Foos) state. When the ports detect loop current, they automatically convert to the Inserv state.

If you have connected the ports to the switch and they remain in the Foos state, you may have a problem with the:

Connection

Switch

Hardware

If you are installing a new board, you will see the manually-out-of-service state (MANOOS). If MANOOS appears for a channel, you will need to convert it to Inserv or Foos by using the second half of this procedure.

NOTE:

If you are already displaying the Voice Equipment screen, begin this procedure at Step 2.

1.Starting at the INTUITY Administration menu, select:

>Voice System Administration

>Voice Equipment

The system responds with the Voice Equipment screen, as shown in

Figure A-4.

Figure A-4. Voice Equipment Screen

Issue 1 June 2000 A-5

Page 67
Image 67
Lucent Technologies Release 3 manual Figure A-4. Voice Equipment Screen