Control cabinet, opened

Control PCB

5.4Lowering the Lift in the Event of a Power Failure

Remove the motor cover hoods. Each spindle can be turned separately at the large drive pulleys with a ratchet (nut size 36) to lower the carriages. When doing this, two persons should lower the front column pair at the same time and then the back column pair.

As soon as the power returns, synchronise the carriages again by pressing "###" and holding it down until all movement stops.

The height difference between the lateral column pair should never be more than 20 mm. The height difference between the column pair in driving direction may not exceed 100 mm!

Important: In the event of a power failure the lifting carriages should only be lowered!