P 4/ 8

Repair

[3]DISASSEMBLY/ASSEMBLY

[3]-3. Motor Section

DISASSEMBLING

(1)Remove Carbon brush as drawn in Fig. 3.

Fig. 3

Carbon brush

(2)Disassemble Fan section as drawn in Fig. 2.

(3)Disassemble Armature as drawn in Fig. 4.

Fig. 4

1.Unscrew four 4x35 Tapping screws and disassemble Fan housing complete.

Fan housing complete

2. Remove Flat washer 8 from

3. Remove Armature from

Armature shaft.

Motor housing.

Flat washer 8

 

 

Armature

Page 4
Image 4
Makita UB1103, UB1102 dimensions Motor Section