P 5/ 8

Repair

[3]DISASSEMBLY/ASSEMBLY

[3]-3. Motor Section (cont.)

DISASSEMBLING

(4)Disassemble Field as drawn in Fig. 5.

Fig. 5

1.Unscrew four 4x18 Tapping screws and remove Handle cover.

Handle cover

2. Disconnect Field lead wires from Switch.

Switch

Field lead wire

3.Disconnect Ring terminals from Brush holders with a Slotted screwdriver.

4.Unscrew two 5x40 Tapping screws and remove Field from Motor housing.

Ring terminal

Note:

Tapping the edge of Motor housing with a plastic hammer enables Field to be removed easily.

Field

Field

Page 5
Image 5
Makita UB1102, UB1103 dimensions Disassembly/Assembly