SPECIFICATIONS

SPECIFICATIONS

Vacuum Tubes:

 

2 x 300B, 2 x 6SL7GT

 

 

2 x 5AR4, 2 x OD3

Lamp type

 

1/4 X 1 1/4, 12 volt, .15 amp

Fuse type

120VAC operation:

MDL2, 2 AMP / 250 Volt

 

220VAC operation:

MDL1, 1 AMP / 250 Volt

 

 

SLO-BLO

Gain

 

18 dB at max Volume

 

 

1 volt in = 8 volts out

Noise Floor

 

typically -70 dB 1Hz - 100 kHz

Signal to noise

 

typically 105 dB A WGT 20-20K

Frequency Response

 

5 Hz to 50 kHz @ +/- 1 dB

Distortion

 

THD+N = -80 dB (.01 %)

zero "crossover" distortion, mostly 2nd harmonic, unmeasurable after 5th

Volume control "Left / right tracking"

1/10 dB

Volume control "steps"

-∞,-70,-60,-50,-46, -44,-42,-40,-38,-36,-34, etc, -12,-10, -6, 0

Input Impedance

 

100 Kohm

Output Impedance

 

100 ohms

Output Power (100 ohm Headphones)

1W (10 V RMS) (28 V P-P)

Output Power (600 ohm Headphones)

1W ( 25 V RMS) (70 V P-P)

Power Consumption

 

170 Watts (1.4 A @ 120VAC)