Marantz CDR510 CD code, CD-Rcode, Function, Control commands, Status data transmission, RC-5Codes

Models: CDR510

1 57
Download 57 pages 25.94 Kb
Page 53
Image 53
Control commands:

CTS/RTS hardware flow control

 

Typical Host

 

CDR510

 

 

 

RTS send

 

CTS out

Not Busy

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Normal)

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Busy

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timing chart

RTS

CTS

RxD

TxD

Control commands:

The control command packets have a data length of 7~10 bytes. ASCII codes from 0x00 to 0x7f are used to receive serial data. At the transmission end, take steps to convert the ASCII codes into HEX data to set the data in the data packets. CR (0x0d) is added as the data packet delimiter.

Example: Scroll command (ASCII code @12011)

@

1

2

0

1

1

CR

0x40 0x31 0x32 0x30 0x31 0x31 0x0d

When transmitting commands consecutively, put more than 100ms blank between commands.

Status data transmission:

The status data packets have a fixed data length of 8 bytes. ASCII codes from 0x00 to 0x7f are used to transmit serial data. For this reason, the ASCII codes are converted into HEX data before the data is set in the data packets and transmitted. CR (0x0d) is added as the data packet delimiter.

Example: Transmission "Power ON" (ASCII code @120PRON)

@

1

 

2

 

0

 

P

 

R

O

 

N

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x40

0x31

 

0x32

 

0x30

 

0x50

 

0x57

0X4f

 

0x4e

 

0x0d

RC-5 Codes

Remote control Model RC330, (not supplied – available from Marantz Professional) can control the CDR510 using these RC-5 codes. The CDR510 receives the codes listed in the table below from the infrared remote control sensor on the front of the unit and also the REMOTE RC-5 IN/OUT jacks.

 

CD code

 

CD-R code

 

 

 

 

 

 

 

 

 

Function

System(dec)

Command(dec)

 

System(dec)

Command(dec)

 

 

 

 

 

 

 

 

 

 

 

 

 

0 _ Space

20

00

 

26

00

 

1 ABC

20

01

 

26

01

 

2 DEF

20

02

 

26

02

 

3 GHI

20

03

 

26

03

 

4 JKL

20

04

 

26

04

 

5 MN

20

05

 

26

05

 

6 OPQ

20

06

 

26

06

 

7 RST

20

07

 

26

07

 

8 UVW

20

08

 

26

08

 

9 XYZ

20

09

 

26

09

 

PLAY

20

53

 

26

53

 

STOP

20

54

 

26

54

 

PAUSE

20

48

 

26

48

 

NEXT

20

32

 

26

32

 

PREVIOUS

20

33

 

26

33

 

FF

20

52

 

26

52

 

REW

20

50

 

26

50

 

PROGRAM

20

36

 

26

36

 

CANCEL/DELETE

20

49

 

26

49

 

SCROLL

20

11

 

26

11

 

AMS (intro scan)

20

43

 

26

43

 

TEMPO RESET

20

37

 

-

-

 

REC

-

-

 

26

55

 

OPEN/CLOSE

20

45

 

26

45

 

DISPLAY

20

15

 

26

15

 

ENTER

20

87

 

26

87

 

MENU/STORE

20

82

 

26

82

 

REPEAT

20

29

 

26

29

 

CD

20

63

 

-

-

 

CD-R

-

-

 

26

63

 

TR.INCR

-

-

 

26

114

 

- 53 -

Page 53
Image 53
Marantz CDR510 manual CD code, CD-Rcode, Function, Control commands, Status data transmission, RC-5Codes