19
Web Interface (continued)
OSD Configuration & IMD
The OSD Configuration & IMD page is shown below:
Use the first section of the OSD & IMD page to set the protocol pass-through settings:
o Set Protocol (Image Video, TSL) – Select the protocol type to be passed through the NCB-1004. No te that
this option must be set according to the protocol that is applied to the Control In input on the NC B-1004.
o Pass-Through (On, Off) – Enable or disable the pass-through of Image Video or TSL protocol.
o Read Protocol Type – Refresh the Protocol Type display in the Target Monitor page.
o Read TSL Status – Read the TSL error status. Results are displayed in the Message Box at the bottom of the
page.
Use the left-hand section of the page to configure the OSD with following commands:
o IMD State (Off, On)
o Status Display (Off, On)
o Timecode (Off, LTC, VITC)
o Audio Monitor (Off, On)
Use the left-hand section of the page to configure the In-Monitor Display:
o Show IMD Address – This command displays the current of each monitor on each screen.
o Set IMD Intensity (0-100)
o Send IMD Alignment (Left, Center, Right) – Set the fixed string alignment of a monitor.
o Send IMD Color (Red, Green, Yellow/Amber) – Set the fixed string color of a monitor.
o Send IMD String – Set the fixed string in a monitor.
o Send IMD Name – Set the IMD Name (S/N) of a monitor.
o Get IMD Name – Get the IMD Name (S/N) of the selected monitor.
o Show IMD – Show the fixed string on a monitor.
o Show IMD Name – Show the IMD Name on a monitor.