CLEARANCES

OUTSIDE INSTALLATION

SAMPLE INSTALLATION (FOR REFERENCE ONLY)

2" MINIMUM CLEARANCE TO COMBUSTIBLES (EITHER SIDE)

8 FT MIN.

USE ONLY

NON-COMBUSTIBLE

MATERIALS BELOW

TOP OF SPACERS

1 1/2

AIR SPACE CLEARANCE

FIGURE 2

LCL TELESCOPING CHIMNEY CAP (1 REQUIRED)

LCF FLAT

FLASHING

SHOWN (OR EQUIVALENT)

L48 CHIMNEY SECTION

(1 REQUIRED)

EXTERIOR FINISH

MATERIALS

REMOVED FOR CLARITY

METAL SAFETY STRIP (REQUIRED WHEN PLACED ON A COMBUSTIBLE FLOOR)

H2068 HEARTH

EXTENSION OR EQUIVALENT (1 REQUIRED) WHEN PLACED ON A COMBUSTIBLE FLOOR (REFER TO PG. 11)

277/8

(MIN)

23 1/2 (MIN)

28

(MIN)

SCREENED OPENING 76 1/2 (MIN)

16*

SIDE WALL INSTALLATION

* APPLIES WHEN GLASS DOORS ARE INSTALLED

5

MANTEL INSTALLATION

COMBUSTIBLE FRAMING

MEMBERS TO

TOP OF SPACERS

USE ONLY

NON-COMBUSTIBLE

MATERIALS BELOW

TOP OF SPACERS

12"

MAX

COMBUSTIBLE MANTEL

TOP EDGE OF FIREPLACE

18" MIN. FROM FIREPLACE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL.

(MANUFACTURER RECOMMENDATION)

TOP EDGE OF

FIREPLACE OPENING

53D9028. Rev 1 03/03

Page 6
Image 6
Martin Fireplaces SB5400SS manual Mantel Installation Combustible Framing, TOP of Spacers